Data center applications require uninterrupted power supply capability to ensure continuous operation, which is realized by static transfer switch with multiple sources. Traditional static transfer switch has relatively slow transfer speed due to semi-controlled thyristor-based main switches. This article presents a novel ultrafast static transfer switch with resonant turn-off capability for data center applications. There are two major contributions. First, a mixture switch based resonant turn-off circuit is proposed to accelerate the main thyristors turn-off speed thus reducing total transfer time between sources to milliseconds. Second, a flux-match based static transfer algorithm is deployed to limit the reconnecting dynamic inrush current induced by load side power distribution transformers, which alleviates the risk of overcurrent damage of the system. Working principles and design guidelines are demonstrated in detail. A three-phase 480 V/1000 A static transfer switch prototype is implemented. Continuous conduction experiment and resonant turn-off experiment are conducted respectively to validate the thermal and switching performances of the powertrain. System level transfer experiment is conducted at three-phase 480 V/60 A RMS to validate complete operation of the proposed static transfer switch.
Soft start-up in Dual-Active-Bridge (DAB) converters is a significant challenge due to the need to mitigate initial inrush currents. This challenge is even more pronounced in the Stacked Half-Bridge Full-Bridge (SHB-FB) converter incorporating an additional blocking capacitor and is a derivative of the conventional DAB converter. This paper initially assesses the start-up issues introduced by the dc blocking capacitor in the SHB-FB converter, which has received limited attention in existing literature. Then, a multistage soft start-up technique for the SHB-FB converter is proposed, considering the precharging process of the dc blocking capacitor. The technique is first validated through simulations and further experimentally verified with a Gallium Nitride (GaN)-based SHB-FB converter. The start-up challenges arising from the blocking capacitor are addressed, and experimental results show a 74% decrease in the initial inrush current compared with the hard start-up condition.
The Trend of Digitalization in Electric Power distribution has been widely discussed, and there is an increasing adoption of switchgear with digital technologies, as well as digital switchgear. Digital switchgear is paving the future of the electrical industry’s transition to safer, more reliable, and future-proof switchgear solutions. Protection of the busbar in digital switchgear that uses low-power passive instrument transformers (ITs) or sensors requires a distinct set of considerations as compared with conventional ITs used in today’s conventional switchgear. These considerations are explored in this article. Alternative approaches to bus protection are described, and their pros and cons are evaluated.
Fault interruption in high-power dc distribution applications is challenging owing to the fast rate of rise of short circuit currents and the lack of a natural zero crossing in the current. A hybrid dc circuit breaker (HCB) has emerged as a promising solution that synthesizes the fast interruption speed of solid-state breakers with the low on-state losses of mechanical circuit breakers. This work introduces a novel concept of current-limiting (CL) HCB capable of actively clamping the fault current for a few hundred microseconds, thereby ensuring the downstream CB acts first in case of a fault event. This protection coordination scheme guarantees selectivity and prevents loss of coordination. The proof-of-concept prototype is developed using a pair of series-connected IGBTs connected in parallel to varistors as a CL branch. This work carried out a successful CL function of 4.5 kA for 100 mu s and subsequent current interruption within 180 mu s for a di/dt ranging from 4 A/mu s to 40 A/mu s. The article also provides a comprehensive discussion on the selection of semiconductor devices, surge current conduction capability, and current turn-off characteristics based on experimental evaluation of multiple commercially available packages. Analytic calculations of clamping device viability are also analyzed to assess suitability for practical implementation.
This manuscript provides a survey of seminal and state-of-the-art methods for visual guidance and force control in robotic manipulation, with particular interest in combined vision and force methods. Other reviews outline similar methods; however, they present outdated approaches and thus lack recent pertinent breakthroughs. The purpose of this report, therefore, is to provide a holistic review of the most recent research advances in vision and force integration for robotic manipulation and the supporting prior art they rely on. In this document, both visual guidance and force control methods are explored from a historical perspective. Additionally, the general technical approaches to both modes are addressed, and the categorization and classification of visual and force control methods are broken down at a deeper level of granularity. Current use-cases for combined vision and force control are outlined and distinguished from one another in a comprehensive table. Additionally, a survey of the distinct technical methods for combined control schemes is presented. This outline serves not only as a summary of the current landscape in combined vision and force control, but also as a tool for researchers to select ideal visual, force, or combined visual and force guidance methods in technical implementation for robot manipulation.