Railway Technical Research Institute (鉄道総合技術研究所, Tetsudō Sōgō Gijutsu Kenkyūsho), or RTRI (鉄道総研, Tetsudō Sōken), is the technical research company under the Japan Railways group of companies.
Suppressing friction-induced vibration (FIV) in catenary-pantograph systems is critical because it impacts both stable transportation and maintenance costs. Numerous studies have investigated FIV using analytical, experimental, and numerical methods. However, none of these studies considered the sprag angle-the upper-frame angle of the pantograph-although its role in brake squeal has been extensively investigated. This study integrates full-scale experiments, a flexible multibody dynamics (MBD) model, and theory to elucidate the role of the sprag angle in FIV in catenary-pantograph systems. Experiments with an actual pantograph demonstrate that FIV is self-excited, and transitions to impact vibration, and that larger sprag angles and higher friction destabilize the system and shift the dominant FIV frequency. On the numerical side, we propose a fast equilibrium solver for the pantograph that enables efficient flexible MBD simulations. Moreover, complex eigenvalue analysis reproduces the measured stability boundaries, growth rates, and dominant frequencies. Mechanistically, a circulatory matrix induced by Coulomb friction drives mode coupling; the eigenvalues depend strongly on the sprag angle, explaining the observed frequency shifts. The model further shows that effective countermeasures require both adjusting the sprag angle and mitigating mode coupling. We also clarify, theoretically, the relationship between the eigenvalue perturbation and mode displacement methods. The results demonstrate that combining these approaches enables a deeper understanding of FIV and that FIV can be captured, both qualitatively and quantitatively, by a three-degree-of-freedom system. This combined approach advances FIV research and contributes to other fields that address mode coupling.
This study conducted a series of fire tests in a small-scale tunnel with a vertically elongated rectangular crosssection measuring 0.4 m in width and 0.5 m in height. The temperature and flow velocity within a quasi-steady, fire-driven smoke layer running along the center of the ceiling were measured up to a distance of 35 times the tunnel height from the fire source. Based on the observed velocity and temperature rise distributions within the smoke layer perpendicular to the tunnel ceiling, correlations were proposed to predict maximum temperature rise, maximum velocity, and smoke layer thickness at various distances from the fire source. The vertical distributions of velocity and temperature rise in the smoke layer are characterized by peak values and layer thickness across different distances from the fire source, with the layer thickness exhibiting a gradual exponential increase as the smoke moves further from the source. The vertical distribution shapes of velocity and temperature rise remain consistent regardless of the distance from the fire source, even in areas far from the source where the smoke layer thickness cannot be considered constant. Simple empirical equations were developed to represent the distributions of velocity and temperature rise within the smoke layer, specifically in a direction perpendicular to the tunnel ceiling. While acknowledging the challenges of scaling experimental results to full-scale tunnels, the applicability of the temperature distribution correlation to other tunnel models with different dimensions with different vertically elongated rectangular cross-section aspect ratios was confirmed through comparison with both small-scale and full-scale experimental data.
To quantitatively evaluate the nonlinear characteristics near the downtown of Kumamoto City, located in the plain where several building damages occurred during the (Asano, and Iwata, 2016) Kumamoto earthquake sequence, Japan, we investigated the variation of site amplification factors using the earthquake ground motion data of over 200 records and the nonlinear characterization of the shallow subsurface structure. At first, the earthquake ground motions at the seismic station near the downtown of Kumamoto City, which was selected as the test site for the blind predictions in ESG6 (Effects of Surface Geology on Seismic Motion), were categorized into weak ground motions with the observed PGAs (Peak ground accelerations) of smaller than 50 cm/s2 and strong ground motions with the observed PGAs of over 50 cm/s2, respectively, by site amplification factors and DNL (Degree of nonlinearity). Secondly, we optimized Q-factors by fitting to the site amplification factor for weak ground motions. Finally, we applied the equivalent linear method using the nonlinear properties derived from the laboratory test to the ground motions at the rock site observed during the foreshock and the mainshock. As a result, the predictions were in good agreement with the observations in the frequency range of 0.1 to 5 Hz, as the GOF (Goodness-of-fit) shows the reliable scores. In this study, we concluded that nonlinearity does not appear much in the superficial layers at the site, but significantly appears in the middle layer with sand (Vs 190 cm/s2) at a depth of about 10 to 20 m. The effective shear strain of about 1
Contact wire splice fittings are widely used in railway systems to enable partial replacement of locally worn or damaged contact wires. However, their application has long been prohibited in the Japanese Shinkansen system due to concerns regarding loss of contact, accelerated wear, and particularly fatigue fracture. Recent reports from France of fatigue fractures near splice fittings in high-speed operation zones have highlighted the need for quantitative evaluation of splice-induced mechanical effects. This study investigates the applicability of contact wire splice fittings to Shinkansen overhead contact line systems from the viewpoint of fatigue fracture. Dynamic experiments were conducted using a full-scale test rig, and contact wire strain near splice fittings was evaluated over a range of pantograph velocities. The results show that the strain increase remains moderate at low normalized pantograph velocities but increases rapidly as the running velocity approaches the wave propagation velocity of the contact wire. To clarify the underlying mechanisms, a strain estimation method was developed that accounts for the effects of splice bending stiffness and added mass. The method successfully reproduces the experimentally observed trends, revealing that bending stiffness dominates strain increase at lower velocities, whereas splice mass becomes the governing factor at higher normalized velocities. By incorporating empirically identified dynamic effects and aerodynamic uplift of the pantograph, the applicable speed range of splice fittings was discussed in relation to a fatigue fracture reference strain. The results indicate that, from the viewpoint of contact wire fatigue fracture, splice fittings can potentially be applied safely up to a normalized pantograph velocity of approximately 0.6, which represents a conservative guideline within the proposed assessment framework. This study provides a quantitative framework for reassessing the applicability of contact wire splice fittings in high-speed railway overhead contact line systems.