• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Applied Energy

    Applied Energy

    JournalISSN 0306-2619eISSN 1872-9118中科院 工程技术 1区

    年发文量

    研究主题

    论文(28345)

    排序
    1NewOptimal Integration of Power-to-Vehicle and Power-to-Heat Systems to Support Renewable Deployment in Smart Urban Energy Districts
    Ashkan Mohammadbagherzadehmamaghani, Endeshaw Alemu Bekele,Antonio Sgaramella,Lorenzo Mario Pastore,Davide Astiaso Garcia

    Decarbonising smart urban energy districts through distributed renewable generation requires planning frameworks able to capture sector-coupling flexibility, while accounting for the multidimensional trade-offs among technical, economic and environmental objectives. This study aims to address the complexity of energy district planning by applying a multi-objective optimisation framework to assess how Power-to-Heat and Power-to-Vehicle strategies can jointly enhance renewable integration. A residential district is modelled in EnergyPLAN comparing a reference configuration based on electricity grid and gas boilers with electrified scenarios including heating, cooling and transport demand under five electric vehicle penetration levels. For each scenario, photovoltaic, small-scale wind, electric batteries, and thermal storage capacities are optimised by minimising annual costs, critical excess electricity production, and CO2 emissions. Results show that increasing electric vehicle penetration reduces emissions and annual costs, while lowering stationary battery requirements through smart charging flexibility. Beyond a certain level of on-site renewable deployment, further decarbonisation depends primarily on the combined electrification of mobility and domestic end-uses, rather than on additional renewable capacity alone. At intermediate electrification levels, thermal storage supports a solar-dominated mix, whereas higher electric vehicle penetration favours a more balanced renewable mix with reduced storage needs. The fully electrified configuration decreases primary fossil energy consumption, achieving 90% CO2 abatement and reduces annual costs by about 7% compared with the reference case, while reaching 67% self-sufficiency and 79% self-consumption. The findings demonstrate that exploiting heat pumps and electric vehicles for system flexibility can enhance renewable integration and limit local excess electricity production.

    2027
    引用
    AI阅读
    加入学术空间
    2NewPressurized Entrained-Flow Gasification of Biogenic Waste in Regime I and II: from Global CO2-char Burnout Kinetics to Industrial Design Implications
    Weiss Naim, Alexandra Bauermeister, Lukas Springmann,Sebastian Fendt,Hartmut Spliethoff

    This study presents a pressurized, high-temperature kinetic investigation of the char reactivity of biogenic waste in pilot-scale entrained-flow gasification up to 1600 °C. Such analysis is exclusively available for coal, which leaves a critical gap for alternative feedstocks under industrially relevant conditions. By using pressurized kinetic set-ups like a pilot-scale entrained-flow reactor (PiTER) and a thermogravimetric analyzer (pTGA), this work assesses annealing effects, catalytic influences, Regime I-II transition, set-up limits as well as true CO2-char reactivities at near-industrial synthesis gas exit conditions, which serve as design points for the engineering of the gasification process.The transition from chemical to pore-diffusion control occurs between 800 and 850 °C, significantly lower than for coal, undermining the higher catalytic activity of biogenic waste. Activation energies derived from both set-ups show remarkable agreement for Regime II (PiTER: 92.6 kJ/mol; pTGA: 96.5 kJ/mol). The reaction order in Regime II aligns also very well with the Thiele prediction (PiTER: 0.54; Thiele: 0.61). The reactivity in Regime II is successfully verified across different authors and set-ups.The coupling of the required residence time for full conversion with thermodynamic gasifier modelling via Aspen Plus® V14 shows that biogenic waste reduces the required reactor volume from 27.7 m3 to 14.4 m3 for a 200 MWth plant, while maintaining the same syngas yields with 0.07 Nm3/(m3*kg) as of bituminous coal.These findings show the value of pilot-scale kinetic data and establish a validated design framework for CO2-neutral entrained-flow gasifiers, enabling de-risked scale-up, efficient biomass-to-X process design and co-gasification strategies.

    2027
    引用
    AI阅读
    加入学术空间
    3NewOptimal Grid-Forming Distributed Generation Allocation and Sizing in Radial Islanded Microgrids under Single-Feeder Contingencies: A Loadability-Driven Approach
    Nour M. Shabar,Khaled Al Jaafari,Hatem H. Zeineldin,Ehab F. El-Saadany

    The transition from passive distribution systems to actively managed microgrids requires planning frameworks that account for islanded operation under network contingencies. In radial microgrids with inverter-interfaced, droop-controlled distributed generation units (DGs), a single-feeder outage partitions the system into two islands with different generation and load compositions. Under these conditions, DG allocation and sizing, combined with priority-driven load shedding, determine the loadability and curtailment needed to satisfy voltage, frequency, and line-current limits. This paper develops a loadability-driven planning framework for islanded radial microgrids that minimizes the total priority-weighted load shed across all single-feeder contingencies. The planning problem is formulated as a double-stage mixed-integer nonlinear program (MINLP). The outer stage selects DG locations and discrete ratings under a fixed capacity budget using a bound-guided search, while the inner stage determines priority-level loadability factors for each island through deterministic droop-based nonlinear power-flow (NLPF) evaluations subject to DG capability, voltage, frequency, and line-current constraints, with voltage- and frequency-dependent loads. On the IEEE 33-bus microgrid, the selected layout fully serves high-priority loads in all single-feeder contingencies and requires shedding in only two contingencies, with a weighted shedding objective of 0.2013 pu. Under a common NLPF evaluation, it reduces weighted shedding by 91% relative to a layout selected by mixed-integer second-order cone programming (MISOCP), while maintaining operational constraints on voltages, frequency, and line ampacity. Additional studies on droop representation, installed capacity, DG spatial distribution, load prioritization, loss-oriented planning, DG firm-capacity availability, and 141-bus scalability examine the effectiveness and practicality of the proposed contingency-driven planning framework.

    2027
    引用
    AI阅读
    加入学术空间
    4NewToward Real-World-representative Durability Testing of Fuel Cells for Heavy-Duty Transport
    Alex Ferri-Sirvent,Marcos Lopez-Juarez, André Nakaema Aronis,Ricardo Novella

    Low-temperature proton exchange membrane fuel cells are considered one of the most promising technologies for decarbonizing the transport sector due to their high efficiency, fast response, and zero emissions. However, the dynamic and highly transient operating conditions encountered in heavy-duty fuel cell vehicles pose an additional challenge to the development of suitable and durable materials. Developing standardized load profile test methodologies that faithfully reproduce real operating scenarios is a key step toward timely material screening and the harmonization of durability benchmarks across different research facilities. Here we present a Markov Chains-based LPT representative of heavy-duty FCVs application, providing a reproducible model that can be used in other case studies as a reference for investigating different operating conditions to mimic different behaviors in a fuel cell stack, generate experimental data for simulation-based lifetime predictions and allow the development of ASTs. Drive cycle data extracted from TEN-T corridors, processed through a validated LT-PEMFC system model representative of the Toyota Mirai architecture, form the basis of the proposed load profile generation methodology. In this work, the performance in terms of H2 consumption and FC lifetime for a HDFCV operating in real-world conditions is evaluated and directly compared with the performance of the FC system following the developed LPT, showing a high level of fidelity to the representative operating conditions of the LT-PEMFC in heavy-duty vehicle operation.

    2027
    引用
    AI阅读
    加入学术空间
    5NewTowards Reliable DER Integration: A Critical Review of Transmission, Distribution, and Microgrid Coordination Requirements
    Cristian Alcarruz-Olivos, Gabriel Chavez,Sleiman Mhanna,Rodrigo Moreno,Pierluigi Mancarella

    Distributed energy resources (DER) can reduce costs and emissions while enhancing flexibility, reliability, and resilience. Realising this value requires coordination across operation and planning. This critical review follows DER integration from connection requirements, visibility, and economic signals through aggregation and TSO–DSO coordination to transmission and distribution (T&D) planning. It establishes that DER becomes a reliable resource only when capability is defined, availability communicated, network feasibility established, response activated and verified, and responsibility for delivery assigned. The review distinguishes the value of aggregation from the conditions that make it necessary. Portfolio diversity can improve delivery reliability and a common interface can reduce participation costs, while aggregation becomes necessary only when individual DER cannot meet market access, qualification, or delivery requirements for the service at reasonable cost. The required function then determines the architecture, with energy communities, virtual power plants, and microgrids (MGs) addressing collective governance, market coordination, and reliable local supply. In planning, the distribution investment required to access DER flexibility is commonly neglected in transmission planning. Carrying operational evidence into planning requires representing location, availability, response duration, and uncertainty alongside distribution investments needed to access DER flexibility. This joint representation enables coordinated T&D planning and DER and MG options to be consistently compared with network reinforcement and large-scale resources, and to avoid redundant investment. Finally, the paper identifies near-, medium-, and long-term technical, operational, regulatory, and research priorities for implementation.

    2027
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 28345 篇论文

    高被引作者

    作者引用发文
    Jinyue Yan13814167
    Hongxing Yang11637113
    Rui Xiong955772
    Jianzhong Wu919394
    Minggao Ouyang797169
    Luisa F. Cabeza Fabra795462
    Sydney Douglas Probert7498399
    Henrik Lund737826
    Yi-Ming Wei731958
    Hongwen He704364

    高产作者

    作者引用发文
    Sydney Douglas Probert7498399
    Jinyue Yan13814167
    Hongxing Yang11637113
    Jianzhong Wu919394
    Hongjie Jia558385
    Ashwani K. Gupta514578
    Hailong Li442874
    Rui Xiong955772
    Minggao Ouyang797169
    Wenquan Tao344566

    相关期刊

    International Journal of Hydrogen Energy
    Energy Conversion and Management
    Energy
    Renewable Energy
    Frontiers in energy research
    Journal of Energy Storage
    Sustainable Energy Technologies and Assessments
    International Journal of Energy Research
    Renewable and Sustainable Energy Reviews
    Energy Reports