
The role of endovascular thrombectomy (EVT) in acute ischemic stroke due to distal vessel occlusions (DVOs) remains to be clarified. Anatomical complexities in the distal vasculature, such as tortuosity and vessel fragility, render technique selection particularly paramount during EVT. Herein, we present two illustrative cases of anatomically similar DVOs treated with two different techniques at a single institution to frame a discussion of important procedural considerations during EVT for DVO.
Superior cerebellar artery (SCA) aneurysms are rare, accounting for only 1%-2% of all intracranial aneurysms, and are predominantly wide-necked. Due to the typically acute angle between the SCA and the basilar artery, stent delivery to the SCA through the basilar artery in an anterograde approach is technically challenging. In contrast, accessing the SCA from the anterior circulation through the posterior communicating artery is considerably more feasible. This approach to guiding a microcatheter from the anterior to the posterior circulation is called the transcirculation technique. Notably, the stent could be deployed across the entire length of the aneurysm neck via transcirculation, ensuring effective coverage of the target aneurysm. Herein, we present a case of an SCA aneurysm successfully treated with the transcirculation technique (Video 1). This approach may represent a promising alternative for treating wide-necked SCA aneurysms in selected cases with an acute angle between the SCA and the basilar artery. The procedure was performed following informed consent.
Radial access has become more common among interventionalists for neurointerventional procedures due to lower complication rates and patient comfort.1, 2 However, rare but serious complications such as catheter fracture and retention require recognition and investigation of advanced retrieval strategies.3 We present a two-stage case involving a patient in their 70s who initially underwent successful mechanical thrombectomy for left M1 occlusion. Hours later, new onset of neurological deficits led to repeat digital subtraction angiography via right radial access. During catheter withdrawal and after initial medical management of suspected vasospasm, the RIST guide catheter became entrapped and fractured within the axillary artery. Transfemoral access was used to retrieve the distal catheter fragment using a snare technique. Post-retrieval imaging confirmed vessel integrity, though ulnar artery occlusion led to ischemia requiring vascular surgery. This case illustrates a rare complication of radial access and highlights suspected novel technical considerations for retrieval, rescue planning, and catheter system selection.
Cerebrospinal fluid-venous fistula (CSFVF) is an increasingly recognized cause of spontaneous intracranial hypotension (SIH). We present a rare case of a 41-year-old woman with SIH caused by a right S2-S3 CSFVF draining in the right internal iliac vein. Successfully transvenous endovascular embolization using Onyx was performed. This report highlights diagnostic challenges and procedural details, emphasizing the efficacy of endovascular approaches in managing CSFVF in atypical anatomical locations.
BackgroundTransradial mechanical thrombectomy offers reduced complications compared to transfemoral approach but has been limited by the inability to safely deliver large-bore aspiration catheters through a radial sheath. The Food and Drug Administration (FDA)-cleared Zebra laser-cut catheter with 7F (0.087″ inner diameter; 0.096″ outer diameter) and 6F versions (0.074″ inner diameter; 0.083″ outer diameter) addresses this limitation.MethodsWe conducted a retrospective review of 26 patients undergoing transradial mechanical thrombectomy for acute ischemic stroke using the Zebra catheter through radial sheaths at two centers (January-August 2025). Primary outcomes included radial access success, recanalization (Thrombolysis in Cerebral Infarction [TICI] 2b-3), and access-site complications.ResultsMean age was 65.04 ± 12.82, mean National Institutes of Health Stroke Scale (NIHSS) was 20.88 ± 7.87. Radial access success rate was 96.2% (25/26). One conversion to femoral occurred due to catheter herniation at acute innominate-left common carotid angulation with aberrant right subclavian anatomy; the procedure was completed successfully via femoral route using the same system. Successful recanalization (TICI 2b-3) occurred in 88.5% (23/26) of patients. Zebra accommodated aspiration catheters ranging 0.055-0.071″ inner diameter and navigated complex anatomy including tortuous carotid origins with subclavian elevation up to 15 mm. No access-site complications occurred. Mean fluoroscopy time was 23.07 ± 18.24 min with 88.5% of procedures rated "easy" by the operator. Acute aortic branch angles represented the primary anatomical limitation, while distal tortuosity and moderate subclavian elevation were manageable.ConclusionZebra enabled transradial mechanical thrombectomy with high recanalization rates without access-site complications. Zebra succeeded across complex anatomy and demonstrated compatibility with various large bore suction catheters, allowing uniform utilization for thrombectomy in radial versus femoral access.