
This work investigates the unsteady fluctuation of inducer recirculation stemming from the diffuser stall that occurs near the surge condition. Experiments and unsteady numerical simulation were utilized for the investigation. Inducer recirculation is known to occur near the surge occurrence flow rate, where the flow rate has a positive slope of the performance curve and the recirculation extends to the upstream of the impeller inlet when decreasing the flow rate more. However, few papers have investigated the unsteady phenomenon of the recirculation, even though the surge is what causes it. Clarifying the recirculation phenomenon is essential in terms of expanding the operation range to the lower flow rate for centrifugal turbomachinery. This was our motivation for investigating the unsteady oscillation phenomenon of the inducer recirculation. We investigated a single-stage centrifugal blower with the maximum pressure rise ratio of 1.2 and focused on the flow rates near surge occurrence. The blower was equipped with an open type centrifugal impeller, a vane-less diffuser, and a scroll casing. The blower performance and pressure time-history data were obtained by experiments. Unsteady simulations using large eddy simulation (LES) were conducted to investigate the flow field in the blower for each flow rate. The obtained performance curve showed that the positive slope of the pressure rise at the lower flow rate was due to the impeller stall and that the inducer recirculation extending upstream of the suction pipe near the slope of the curve was flat. LES analysis revealed that this inducer recirculation had two typical fluctuation peaks, one at 20% of the rotation frequency and the other at 95%. We also found that the stall cell at the impeller inlet propagated in the circumferential direction and swirled at almost the same frequency as the impeller rotation. In addition, the fluctuation at the diffuser derived from the diffuser rotating stall propagated to the suction pipe.
Highly efficient and concurrent flexible operation are heavy demands on today’s centrifugal compressor units. Diffuser end wall contouring is a measure to delay the incipience of instability and therefore to extend the compressor’s operating range while maintaining efficient performance. In the presented paper, a hubside wall contouring, applied in the vaneless space upstream the diffuser’s leading edge and within the diffuser passage of a state-of-the-art centrifugal compressor with an open impeller is examined. CFD computations are performed for both a baseline diffuser design with parallel channel walls and the hub-side wall contoured diffuser design. Comparisons of characteristic and diffuser stability decisive flow variables are made in perpendicular sections along an extrapolated camber line of the diffuser vane for full span, near shroud and near hub wall. In operating points near the stability limit at two different stage Mach numbers, the stabilizing effect of the hub-side wall contouring on the diffuser flow is clearly shown. In a scale-model test rig, experimental data including pneumatic 5-hole probe data for a full diffuser blade-to-blade passage, static wall pressures at various planes as well as total temperature was measured. The experimental data is utilized for validation of the presented numerical calculations. The flow stabilizing effect of the hub-wall contouring is clearly visible in the measurements, which showed 8% range extension at highest stage Mach number Mu2 = 1.16 and a range extension of 2% at design stage Mach number Mu2 = 1.0.
Recent innovative engine integration systems present interesting prospects for considerable aircraft fuel burn reduction. In this context, the Airbus Nautilius is a patented engine integration concept embedding two Ultra High Bypass Ratio (UHBR) turbofans at the rear of the fuselage so as to take the full benefit of the boundary layer ingestion (BLI). This concept presents very promising power savings compared to classical podded configurations when neglecting the penalty on fan performance. However, as the engine is now working in distorted boundary layer flow conditions, these benefits can be partially offset by an additional fan performance penalty. In order to assess these additional losses and therefore to refine the potential of this concept, a numerical fan design activity has been conducted by Onera on behalf of and in collaboration with Airbus. First, blade design modifications have been applied to a pre-existing UHBR fan stage originally designed for “classical” podded configurations in order to maximize the isentropic efficiency in cruise conditions. The results of this first activity shows that more than half of the fan isentropic efficiency penalty due to the distortion at the engine inlet can be recovered by few design iterations. Secondly, an operability assessment at take-off high-lift conditions has been conducted on the optimized geometry and ensures that the fan stall margin remains acceptable. In conclusion, these results confirm the initial potential and mark an additional step towards a broader assessment of the Nautilius engine integration concept, which shall be further completed by acoustic and aeroelastic studies.
The trend towards increased bypass ratio and reduced core size in civil aero-engines puts a strain on ground-start and relight capability, prompting renewed interest in sub-idle performance modelling. While a number of studies have looked at some of the broad performance modelling issues prevalent in this regime, the effects that bleed can have on sub-idle performance have not been addressed in the literature. During start-up and relight, the unknown variation in bleed flows through open handling bleed valves can have a considerable impact on the compressor’s operating line. This paper combines experimental, numerical and analytical approaches to look at the effect that sub-idle bleed flows have on predicted start-up operating lines, along with their effect on compressor characteristics. Experimental whole-engine data along with a purpose-built core-flow analysis tool are used to assess the effect of bleed model uncertainty on engine performance models. An experimental rig is used to assess the effects of reverse bleed on compressor characteristics and measurements are compared against numerical results. Several strategies for the generation of sub-idle maps including bleed effects are investigated.
The overall fraction of the power produced by renewable sources in the energy market has significantly increased in recent years. The power output of most of these clean sources is intrinsically variable. At present day and most likely in the upcoming future, due to the lack of inexpensive and reliable large energy storage systems, conventional power plants burning fossil fuels will still be part of the energy horizon. In particular, power generators able to promptly support the grid stability, such as gas turbines, will retain a strategic role. This new energy scenario is pushing gas turbine producers to improve the flexibility of their turbomachines, increasing the need for reliable numerical tools adopted to design and validate the new products also in operating conditions far from the nominal one. Especially when dealing with axial compressors, i.e. machines experiencing intense adverse pressure gradients, complex flow structures and severe secondary flows, CFD modelling of offdesign operation can be a real challenge. In this work, a state-of-the art CFD framework for RANS analysis of axial compressors is presented. The various aspects involved in the whole setup are discussed, including boundary conditions, meshing strategies, mixing planes modelling, tip clearance treatment, shroud leakages and turbulence modelling. Some experiences about the choice of these aspects are provided, derived from a long-date practice on this kind of turbomachines. Numerical results are reported for different full-scale compressors of the Ansaldo Energia fleet, covering a wide range of operating conditions. Furthermore, details about the capability of the setup to predict compressor performance and surge-margin have been added to the work. In particular, the setup surge-margin prediction has been evaluated in an operating condition in which the turbomachine experiences experimental stall. Finally, thanks to several on-field data available at different corrected speeds for operating conditions ranging from minimum to full load, a comprehensive validation of the presented numerical framework is also included in the paper.