
BACKGROUND The Micra AV leadless pacemaker allows atrioventricular synchronous pacing through accelerometer-based sensing of atrial mechanical activity (A4 amplitude). However, determinants of sustained atrioventricular synchrony (AVS) in real-world conditions remain poorly defined. OBJECTIVE To identify clinical and echocardiographic predictors of device-derived AVS 1 year after Micra AV implantation, and to assess the association between 1-year AVS and baseline A4 amplitude, and predictors of A4 amplitude. METHODS In patients undergoing Micra AV implantation, baseline clinical and echocardiographic data were collected. One-year AVS was evaluated in patients with ≥80% ventricular pacing using a device-derived index reflecting atrial mechanical sensing. Predictors were identified using MI-LASSO and stepwise regression with bootstrap validation. RESULTS 94 patients were included; high-degree AV block was the primary pacing indication (N = 88). At 1 year, 38 patients had ≥80% ventricular pacing; median AM-VP% was 82.9% (IQR 73.8-87.8) and AVS index was 83.1% (IQR 77.0-87.7). Predictors of device-derived 1-year AVS included older age, higher left atrial reservoir strain rate, lower right atrial volume index, and lower E/e'. For AVS, R2 was 0.80 (MI-LASSO) and 0.55 (stepwise). One-year AVS was strongly associated with baseline A4 amplitude (p < 0.001). Predictors of A4 amplitude included hypertension, absence of prior cardiac surgery, higher TAPSE, higher left atrial reservoir strain and preserved left atrial conduit strain rate. CONCLUSIONS Clinical and echocardiographic characteristics may help identify patients most likely to achieve sustained atrioventricular coupling with Micra AV. Markers of preserved atrial function, limited atrial remodelling, and lower filling pressures may further refine patient selection.
Background Transcatheter edge-to-edge mitral valve repair (M-TEER) represents a safe treatment modality for patients with high-grade mitral regurgitation (MR). While clinical decision-making concerning the referral of suitable candidates for M-TEER is guided primarily by clinical and echocardiographic parameters, the potential of hemodynamic parameters obtained at the time of screening in predicting treatment outcomes has not been sufficiently investigated. Methods All patients who underwent M-TEER and who provided sufficient right heart catheterisation (RHC) data prior to M-TEER were enrolled for analysis. The investigated hemodynamic parameters were analysed descriptively and their associations with survival were estimated by univariable Cox regression analysis and Kaplan-Meier's analysis. Results A total of 94 patients were analysed, of whom 92.6% (87/94) had concomitant pulmonary hypertension (PH). Analysis of the hemodynamic profile revealed that 46.8% (44/94) of patients had advanced-stage congestive heart failure with a cardiac index < 2 L/min/m(2), and 68% (64/94) of patients had a cardiac power index <0.5 W/m(2). According to the results of the Kaplan-Meier and Cox regression analyses, a systolic pulmonary artery pressure (sPAP) > 60 mmHg and a mean right atrial pressure (RAP) > 20 mmHg were proven to be significant predictors of long-term survival after M-TEER. Conclusions Analysis of the hemodynamic profile, specifically the identified predictors, contributes to the improved identification of scenarios associated with a favourable prognosis in patients undergoing M-TEER.
Background: Successive European guideline updates have modified the estimation and categorisation of cardiovascular risk. The transition from the Belgian SCORE calibration to SCORE2 in 2021, followed by revision of SCORE2 thresholds in 2025, may substantially alter clinical interpretation without changes in individual patient characteristics.Methods: Adults aged 40-69 years in primary prevention were retrospectively included from two Belgian centres. Both cohorts were pooled into a single analytical population. Cardiovascular risk was assessed using the HDL-corrected SCORE-Belgium model (2019), SCORE2 (2021), and the updated SCORE2 thresholds (2025), applied to identical baseline data. Low and moderate categories were harmonised. Reclassification was analysed descriptively.Results: Among 413 individuals, 84.3% were classified as low-moderate risk with SCORE-Belgium, 11.6% as high risk, and 4.1% as very high risk. With SCORE2 (2021), 58.8% were categorised as high risk and 7.3% as very high risk. Application of the 2025 thresholds reversed this distribution: 93.5% were classified as low-moderate risk, 6.5% as high risk, and none as very high risk. These variations affected largely the same individuals and occurred despite identical underlying risk estimates.Conclusion: Guideline updates markedly influence cardiovascular risk categorisation in primary prevention. The changes observed are predominantly attributable to the definitions of thresholds, rather than to differences in the underlying risk estimates. Risk categories should, therefore, be interpreted in the context of the specific assessment framework employed. In addition, supplementary methods for refining individual risk remain necessary.