Detection of high impedance faults (HIF) has been one of the biggest challenges in the power distribution network. The low current magnitude and diverse characteristics of HIFs make them difficult to be detected by over-current relays. Recently, data-driven methods based on machine learning models are gaining popularity in HIF detection due to their capability to learn complex patterns from data. Most machine learning-based detection methods adopt supervised learning techniques to distinguish HIFs from normal load conditions by performing classifications, which rely on a large amount of data collected during HIF. However, measurements of HIF are difficult to acquire in the real world. As a result, the reliability and generalization of the classification methods are limited when the load profiles and faults are not present in the training data. Consequently, this paper proposes an unsupervised HIF detection framework using the autoencoder and principal component analysis-based monitoring techniques. The proposed fault detection method detects the HIF by monitoring the changes in correlation structure within the current waveforms that are different from the normal loads. The performance of the proposed HIF detection method is tested using real data collected from a 4.16 kV distribution system and compared with results from a commercially available solution for HIF detection. The numerical results demonstrate that the proposed method outperforms the commercially available HIF detection technique while maintaining high security by not falsely detecting during load conditions.
Load-shedding is an effective control strategy for realization of the power supply-demand balancing. The balancing supply and demand is a crucial issue for power system stability. In this paper, based on IEC 61850 protocols, a supervisory control and data acquisition (SCADA) platform of dynamic load-shedding (DLS) technology in microgrid (MG) is built. Integrating of SCADA and IED (intelligent electronic device), the proposed technology can fetch the information of power generation, power consumption, and MG structure in real time to evaluate the appropriate amount of load to be shed. The proposed DLS technology has been verified on the simulated MG in Qimei Island, Penghu, Taiwan. Compared with conventional methods, the simulation results verify that the proposed DLS provides the fast and precise load-shedding in different loading scenarios. The proposed method has the superiority in reducing the amount of load-shedding and shedding time.
With increasing adoption of residential PV systems, net load forecasting is gradually shifting from forecasting pure load to forecasting pure load with PV generation. This paper explicitly compares two methods of net load forecasting for systems with high behind-the-meter (BTM) PV penetration. The first method is an additive method, in which PV generation and pure load are forecasted separately and combined to produce a net load forecast. First, a disaggregation algorithm is applied to aggregate net load measurements of residential homes to separate the pure load and PV generation. Then, a long short-term memory (LSTM) model is used to forecast pure load and PV separately using the historical disaggregated pure load and PV, respectively, and weather factors. The results are combined to generate a net load forecast. The additive model is compared to a direct net load forecast from an LSTM model. Results show that over the five-month test horizon, the additive method decreases the root mean square error (RMSE), maximum absolute error, and mean absolute error (MAE) of the net load forecast by 6.13%, 3.63%, and 6.06% respectively, compared to the direct method.
In this research work, a new method which determines the individual harmonic voltage contributions of the EAF plants supplied from a point of common coupling (PCC) to the PCC voltage is presented. EAFs are one of the most significant sources of the harmonics, especially the uncharacteristic ones, therefore it is important to be able to discriminate the amount of individual contributions from the feeders of a PCC supplying multiple EAFs. The proposed method uses the relationship derived between the correlation coefficient of the PCC voltage and the feeder current waveforms and the harmonic voltage contribution of each plant supplied from the PCC. The main idea is based on the fact that harmonic voltage at the PCC is a result of the additive effect of voltage drops on the source side impedance of the power system caused by the individual feeder currents. After computing the Pearson correlation coefficients at each harmonic frequency using 10-cycle synchronized feeder current and PCC voltage waveforms, harmonic voltage contribution of the related feeder is obtained using the proposed method. This procedure can be repeatedly used to obtain the contribution of each EAF plant at each frequency component. Field measurements from a PCC supplying multiple EAF plants are used to verify the results and the performance is compared with the previously proposed methods. With a specified source side impedance by the utility, the proposed approach is a fast method of obtaining the harmonic responsibilities, since no real-time impedance measurements are required and no need for the measurements of the other feeders to compute the contribution of a specific feeder in contrast to some other methods. The proposed method can be easily adapted as a real time harmonic contribution detection tool for the power quality analyzers, all of which have synchronized voltage and current waveform measurements.
In an inductive power transfer (IPT) system, various magnetic materials have difference characteristics in enhancing the degree of coupling and misalignment tolerance between the primary and secondary coils. However, the iron losses in ferromagnetic materials may decrease the transfer efficiency of the IPT system significantly. Therefore, in this study, performance and misalignment tolerance of IPT systems with four types of ferromagnetic materials are investigated. Firstly, an equivalent circuit model of the IPT system is established and the variations of system efficiency with different ferromagnetic materials are also revealed. Then, a 3-D finite element analysis (FEA) model of the magnetic coupler is established. In addition, loss test platform is established to obtain the accurate loss coefficients. Finally, the transfer efficiency and magnetic field distributions are both investigated. The results show that the high efficiency and magnetic flux density can be achieved when nanocrystalline core with vertical laminations is used.