• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Clinical Chemistry and Laboratory Medicine

    Clinical Chemistry and Laboratory Medicine

    JournalISSN 1434-6621eISSN 1437-4331中科院 医学 2区

    年发文量

    研究主题

    论文(13907)

    排序
    1NewAn LR-based Risk Stratification Framework for Assessing Interlaboratory Variability in HEp-2 IFA Pattern Interpretation
    Chaochao Zhang,Yingxin Dai, Dan Cao, Rong Chen,Zhiyuan Gao, Yifan Gong, Anni Guo, Xiaowei Huang,Aiping Liu, Tiantian Liu, Ce Shi,Yi Sun,

    Objectives Interlaboratory variability in HEp-2 indirect immunofluorescence assay (IFA) interpretation remains a major challenge. Conventional agreement metrics quantify disagreement but do not distinguish discrepancies by diagnostic relevance. We aimed to develop a likelihood ratio (LR)-based framework for clinically informed assessment of interpretation variability. Methods Pattern-specific positive LRs were derived from 33,690 routine HEp-2 IFA records and used to classify patterns into four risk tiers. A pattern discrepancy score (PDS) was developed to quantify discrepancies according to risk-tier displacement. Interlaboratory variability was assessed using a standardized 200-specimen panel tested by 18 laboratories, and diagnostic performance was explored in six laboratories. Results Pattern disagreement rates ranged from 17.5 to 50.0 %. PDS strongly correlated with disagreement rate (Spearman's rho=0.936, p<0.001), but laboratories with similar disagreement rates differed in cross-tier discrepancy distribution. Most discrepancies remained within the same risk tier; among discordant interpretations involving high-risk reference patterns, 20.4 % crossed into another tier. Pattern concordance varied markedly, while titer agreement was moderate to almost perfect (weighted kappa, 0.569-0.821). Across six laboratories, diagnostic performance varied (Youden Index, 0.391-0.617), but was not significantly associated with interpretation consistency. Conclusions HEp-2 IFA interpretation variability differs in both frequency and potential diagnostic relevance. The LR-based framework and PDS complement conventional agreement measures by identifying discrepancies that alter diagnostic risk classification, potentially supporting risk-oriented proficiency assessment and targeted quality improvement.

    2026
    引用
    AI阅读
    加入学术空间
    2NewPopulation-specific Pediatric Reference Intervals for Complete Blood Count in Vietnamese Children and Their Impact on Clinical Classification
    Dien Minh Tran, Anh Quynh Mai,Phuc Huu Phan,Tung Viet Cao,Mai Thi Chi Tran,Ronda F. Greaves,Tze Ping Loh,Duyen Thi Nguyen

    Objectives To establish age- and sex-specific reference intervals (RI) for complete blood count (CBC) parameters in healthy Vietnamese children aged 0 to <19 years and assess the impact of applying locally derived vs. non-local pediatric RI on abnormal flagging and clinical classification. Methods A community-based cross-sectional study included 3,885 healthy Vietnamese children aged 0 to <19 years recruited through school-based health screening programs between April 2024 and November 2025. Peripheral venous blood samples were analyzed using the Sysmex XN-9000 hematology analyzer under standardized pre-analytical and analytical conditions with internal and external quality control. Outliers were excluded using the Tukey interquartile range method. Age and sex partitions were established through an integrated assessment of visual inspection, the Mann-Whitney U test, Cliff's delta, the Harris-Boyd method, and biological and clinical considerations. Reference intervals were established according to CLSI EP28-A3c using a nonparametric approach (2.5-97.5th percentiles), with 90 % confidence intervals estimated by bootstrap. Results All CBC parameters showed age-related variation, supporting age-specific RI. Sex differences were limited to erythrocyte parameters, including red blood cell count, hemoglobin, and hematocrit, emerging after puberty; sex partitioning was unnecessary for most analytes. Application of the Vietnamese vs. CALIPER reference intervals in an outpatient cohort resulted in bidirectional reclassification, with 0.0-32.6 % of CALIPER-abnormal results reclassified as normal and 0.0-24.4 % of CALIPER-normal results reclassified as abnormal, depending on the analyte. Conclusions This study establishes population-based pediatric CBC RI for Vietnamese children. Non-local pediatric RI may alter abnormal flagging and result interpretation in routine practice.

    2026
    引用
    AI阅读
    加入学术空间
    3NewAnemia Reflex Testing As a Proof of Concept for Value-Based Laboratory Medicine: from Payment for Tests to Value for Diagnostic Services
    Tommaso Trenti, Sabrina Buoro

    etiological hypothesis, appropriateness of second-line testing, repeat venipunctures and visits, time to clinical action, diagnostic yield, clinician acceptance of interpretative reporting, patient-relevant outcomes and total resources used across the diagnostic episode

    2026
    引用
    AI阅读
    加入学术空间
    4NewValidation of an LC-Q-TOF “hires Mass-fix” Assay for Improved Sensitivity and Specificity of M-protein Detection
    Ryan W. Pearce,Mindy C. Kohlhagen,Mark A. Martinez,Maria A.V. Willrich,Dragan Jevremovic, Jonathan Coker,David L. Murray

    Abstract Objectives To validate a blood-based liquid chromatography quadrupole time-of-flight mass spectrometry (MS) method “HiRes Mass-Fix” as a fit-for-purpose, patient-specific method for detecting low level M-proteins in patients who have reached negativity by MALDI-TOF MS “Mass-Fix”. Methods Analytical validation included precision, accuracy, analytical measurement interval, limit of detection, specificity, ion suppression, carryover, and extracted-sample stability. Clinical performance was assessed by comparing 174 patients with bone marrow (BM) measurable residual disease (MRD) by next-generation flow cytometry (NGF) to both Mass-Fix and HiRes Mass-Fix. Results HiRes Mass-Fix demonstrated acceptable precision, accuracy, linearity, specificity, and stability for its intended use, with an average limit of detection of 3.8 mg/L. HiRes Mass-Fix detected M-proteins in 41 of 58 Mass-Fix negative samples. This raised blood MRD positivity from 62 to 89 % against a BM NGF positivity rate of 51 %. Blood-BM agreement fell from 71 % (kappa 0.43) by Mass-Fix to 58 % (kappa 0.15) by HiRes Mass-Fix, driven by blood-positive/BM-negative discordance. IgG was overrepresented among discordant cases (68 vs. 45 %, p=0.003). Conclusions HiRes Mass-Fix was successfully validated and demonstrated to increase M-protein detection in samples negative by Mass-Fix. IgG recycling may explain the blood-positive/BM-negative discordance, and serial measurements will be needed to distinguish residual M-protein from ongoing production. Blood-based M-protein measurement is a less invasive, lower-cost alternative to bone marrow biopsy for ongoing patient monitoring.

    2026
    引用
    AI阅读
    加入学术空间
    5NewA Practical Approach to Assay Imprecision Evaluation for Clinical Laboratory Professionals: from Concept to Application
    Jesper Vestermark Johansen,Rosita Zakaria,Hamit Hakan Alp, Christopher-John Farrell, Mai Tran,Chung Shun Ho,Elvar Theodorsson,Corey Markus,Ronda F. Greaves

    Abstract Evaluating assay imprecision is fundamental in validating and verifying analytical methods within clinical laboratories. Imprecision quantifies random variability, providing the foundation to assess analytical performance, estimate measurement uncertainty, and support reliable patient care. However, despite clear international guidance, many laboratories struggle to implement these protocols due to limited resources, statistical complexity, and varying clinical contexts. This review provides a practical framework for laboratory professionals to understand, design, perform, and interpret imprecision studies using both comprehensive analysis of variance (ANOVA) models and simplified alternatives. Rather than treating imprecision as a purely statistical exercise, we focus on translating theoretical concepts into flexible, scalable applications for laboratories with varying capacities. The article concludes with several practical core principles for modern imprecision studies.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 13907 篇论文

    高被引作者

    作者引用发文
    Mario Plebani19908460
    Giuseppe Lippi19600341
    Mauro Panteghini6019193
    Ana-Maria Simundic366368
    Brandon Michael Henry349236
    Sverre Sandberg335594
    Gian Luca Salvagno332164
    Wolfgang Herrmann306258
    Ferruccio Ceriotti275366
    Stefanie W Benoit27213

    高产作者

    作者引用发文
    Mario Plebani19908460
    Giuseppe Lippi19600341
    Mauro Panteghini6019193
    Martina Zaninotto196794
    Sverre Sandberg335594
    Etienne Cavalier156282
    Joris R. Delanghe183480
    Cobbaert Christa M86872
    Aldo Clerico241872
    Ana-Maria Simundic366368

    相关期刊

    Annals of clinical biochemistry
    Critical reviews in clinical laboratory sciences
    Clinical Biochemistry
    Scandinavian journal of clinical and laboratory investigation
    Reviews In Medical Virology
    Journal of Thrombosis and Haemostasis
    Clinical Chemistry
    Clinica Chimica Acta
    Journal of Clinical Virology
    Infection