![IEEE International Conference on Robotics and Automation : ICRA : [proceedings]](https://originalfileserver.aminer.cn/sys/aminer/magazine.png)
Endoscopic Submucosal Dissection (ESD) is an effective minimally invasive approach to removing colon cancer, yet it is underutilized, since it is challenging to learn and perform. To promote the adoption of ESD by making it easier, we propose a system in which two small, flexible robotic manipulators are delivered through a colonoscope. Our system differs from prior robotic systems aimed at this application in that our manipulators are small enough to fit through a clinically used colonoscope. By not re-engineering the colonoscope, we maintain overall system diameter at the current clinical gold standard, and streamline the path to eventual clinical deployment. Our concentric push-pull robot (CPPR) manipulators offer dexterity and simultaneously provide a conduit for grasper or cutting tool deployment. Each manipulator in our system consists of two push-pull tube pairs, and we describe how they are actuated. We describe for the first time our approach to compensating for undesirable CPPR tip motion induced by differences in the tubes' transmission stiffness. We also evaluate the workspace of the manipulators and demonstrate teleoperation in a point-touching experiment. Lastly, we demonstrate the ability of the system to resect tissue via ex vivo animal experiments.
Robotic platforms provide consistent and precise tool positioning that significantly enhances retinal microsurgery. Integrating such systems with intraoperative optical coherence tomography (iOCT) enables image-guided robotic interventions, allowing autonomous performance of advanced treatments, such as injecting therapeutic agents into the subretinal space. However, tissue deformations due to tool-tissue interactions constitute a significant challenge in autonomous iOCT-guided robotic subretinal injections. Such interactions impact correct needle positioning and procedure outcomes. This paper presents a novel method for autonomous subretinal injection under iOCT guidance that considers tissue deformations during the insertion procedure. The technique is achieved through real-time segmentation and 3D reconstruction of the surgical scene from densely sampled iOCT B-scans, which we refer to as B5-scans. Using B5-scans we monitor the position of the instrument relative to a virtual target layer between the ILM and RPE. Our experiments on ex-vivo porcine eyes demonstrate dynamic adjustment of the insertion depth and overall improved accuracy in needle positioning compared to prior autonomous insertion approaches. Compared to a 35% success rate in subretinal bleb generation with previous approaches, our method reliably created subretinal blebs in 90% our experiments. The source code and data used in this study are publicly available on GitHub.
Robot-assisted bite acquisition involves picking up food items with varying shapes, compliance, sizes, and textures. Fully autonomous strategies may not generalize efficiently across this diversity. We propose leveraging feedback from the care recipient when encountering novel food items. However, frequent queries impose a workload on the user. We formulate human-in-the-loop bite acquisition within a contextual bandit framework and introduce LINUCB-QG, a method that selectively asks for help using a predictive model of querying workload based on query types and timings. This model is trained on data collected in an online study involving 14 participants with mobility limitations, 3 occupational therapists simulating physical limitations, and 89 participants without limitations. We demonstrate that our method better balances task performance and querying workload compared to autonomous and always-querying baselines and adjusts its querying behavior to account for higher workload in users with mobility limitations. We validate this through experiments in a simulated food dataset and a user study with 19 participants, including one with severe mobility limitations. Please check out our project website at: emprise.cs.cornell.edu/hilbiteacquisition/.
Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes as an effective alternative to more invasive surgical procedures. However, the outcome of needle-based approaches relies heavily on the accuracy of needle placement, which remains a challenge even with robot assistance and medical imaging guidance due to needle deflection caused by contact with soft tissues. In this paper, we present a novel mechanics-based 2D bevel-tip needle model that can account for the effect of nonlinear strain-dependent behavior of biological soft tissues under compression. Real-time finite element simulation allows multiple control inputs along the length of the needle with full three-degree-of-freedom (DOF) planar needle motions. Cross-validation studies using custom-designed multi-layer tissue phantoms as well as heterogeneous chicken breast tissues result in less than 1mm in-plane errors for insertions reaching depths of up to 61 mm, demonstrating the validity and generalizability of the proposed method.
In minimally invasive procedures such as biopsies and prostate cancer brachytherapy, accurate needle placement remains challenging due to limitations in current tracking methods related to interference, reliability, resolution or image contrast. This often leads to frequent needle adjustments and reinsertions. To address these shortcomings, we introduce an optimized needle shape-sensing method using a fully distributed grating-based sensor. The proposed method uses simple trigonometric and geometric modeling of the fiber using optical frequency domain reflectometry (OFDR), without requiring prior knowledge of tissue properties or needle deflection shape and amplitude. Our optimization process includes a reproducible calibration process and a novel tip curvature compensation method. We validate our approach through experiments in artificial isotropic and inhomogeneous animal tissues, establishing ground truth using 3D stereo vision and cone beam computed tomography (CBCT) acquisitions, respectively. Our results yield an average RMSE ranging from 0.58 ± 0.21 mm to 0.66 ± 0.20 mm depending on the chosen spatial resolution, achieving the submillimeter accuracy required for interventional procedures.