• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    IEEE Transactions on Dielectrics and Electrical Insulation

    IEEE Transactions on Dielectrics and Electrical Insulation

    JournalISSN 1070-9878eISSN 1558-4135中科院 工程技术 2区

    年发文量

    研究主题

    论文(8559)

    排序
    1Physics-Guided Terahertz Dielectric Spectroscopy for Aging Assessment of Transformer Oil under Different Moisture Levels
    Jiangchun Yu,Enze Zhang, Honghao Xie, Yihang Deng,Chaohai Zhang

    Assessing the aging of mineral insulating oil is essential for the dielectric reliability of oil-immersed power transformers. Terahertz time-domain spectroscopy (THz-TDS) non-destructively probes the dielectric changes caused by aging, but the measured spectra are also shifted by the initial moisture level of the oil, which limits the generalization of data-driven aging classifiers to an unseen moisture level. This paper proposes a physics-guided terahertz dielectric response learning (PG-TDRL) framework for assessing transformer oil aging across different initial moisture levels. The absorption coefficient and dielectric loss tangent are extracted from THz-TDS measurements as physically interpretable descriptors. A Fisher analysis of the training conditions alone identifies the terahertz bands that best separate the aging stages, and a physics prior layer softly emphasizes them. A spectral encoder and a prototype classifier are further regularized by a sample-level contrastive alignment loss that reduces the feature drift caused by the moisture condition. Under a leave-one-condition-out protocol on 336 THz-TDS measurements from 42 aged oil samples, PG-TDRL achieves 94.6% accuracy and 94.5% macro-F1, outperforming representative domain generalization methods. The results indicate that PG-TDRL makes terahertz aging assessment of transformer oil more robust to the initial moisture level.

    2026
    引用
    AI阅读
    加入学术空间
    2Cable Length Induced Distortion of Polarization and Depolarization Current Characteristics and Its Correction
    Xiaoyan Cao,Kai Zhou,Zerui Li,Siyan Lin, Fan Yang,Mingzhi Li

    This study investigates the cable length induced distortion in polarization and depolarization current (PDC) based insulation diagnosis and proposes a correction method to improve the reliability of characteristic parameter extraction for long cables. PDC measurements are first performed on cables with different lengths. The DC conductivity and tanδ are calculated and compared. The results show that tanδ is significantly increasing as the cable length increases, indicating that cable length introduces a non-negligible distortion into the extracted diagnostic parameters. To analyze this phenomenon, the polarization and depolarization processes of cables with different lengths are studied using an equivalent circuit model of PDC measurement. The corresponding diagnostic parameters are calculated and compared with the actual insulation response. It is found that when the cable length reaches to the point where the cable capacitive reactance is less than or equal to the the current-limiting resistor, a significant deviation appears in the tanδ derived from PDC measurement. This deviation is further interpreted using the Extended Debye Model, which clarifies the mechanism of cable-length-induced distortion in PDC characteristics. To eliminate this effect, a correction method based on singular value decomposition (SVD) is proposed. The proposed method is applied to long submarine cables, and the corrected results verify its validity and provide a reference for promoting the field application of the PDC measument.

    2026
    引用
    AI阅读
    加入学术空间
    3The Application of Surface Partial Discharge Optical Radiation for Assessment of Pollution Degree of External Insulation
    Alexander G. Ovsyannikov, Roman S. Arbuzov, Nikolay A. Shvets, Dmitry S. Zharich

    Sudden flashovers of polluted and wetted line insulation lead to significant power outages. For this reason, monitoring the pollution degree of insulation is very important. This research develops a novel methodology for remote assessment of pollution degree on high-voltage external insulation using the analysis of surface partial discharge radiation. Experimental investigations establish that spectral properties of surface discharges exhibit systematic and distinct variation, correlated with pollution levels: from predominantly blue-violet emissions on clean surfaces toward yellow-orange tones on polluted insulators. A quantitative color ratio of surface discharge radiation demonstrates a significant linear correlation with directly measured surface conductivity and enables the non-invasive determination of insulation pollution level, timely washing and cleaning of insulators when necessary.

    2026
    引用
    AI阅读
    加入学术空间
    4Partial Discharge Based on Charge Behavior under AC/DC Superimposed Harmonic Voltage
    Hongbin Wu, Zhaoyang Kang, Zichao Yuan, Fanbo Meng,Fuqiang Ren,Hongshun Liu,Dongxin He,Qingquan Li

    The valve-side main insulation of converter transformers is simultaneously subjected to power-frequency AC, DC, and harmonic electric fields. The electric field distortion caused by charge behavior under complex electric fields makes partial discharge (PD) more likely to occur. Based on the measured voltage waveform under the low-valve-hall Y/Δ connection of a converter transformer, the PD and charge characteristics of oil-pressboard insulation under needle-plate electrodes are experimentally investigated. This AC/DC superimposed harmonic voltage is hereafter referred to as the Y/Δ voltage. Combined with discharge simulation capable of mapping experimental charge data, the effect of voltage waveform steepness on PD is mainly studied from the perspective of charge. The results show that the density at the peak energy-level of the deep traps in the pressboard under the Y/Δ voltage is 19.32×109 m-3·eV-1. The maximum electric-field distortion rate reaches 33.6 %, which is 45.5 % higher than that under the AC/DC composite voltage with a ratio of effective values of 1:1. The electric-field distortion induced by space charge accumulation causes some PD pulses to appear on the falling edge of the voltage. Simulations show that high waveform steepness causes multiple stagnation events during the lateral evolution of the discharge streamer, thereby increasing the average discharge magnitude and producing a multi-peak discharge distribution under the Y/Δ voltage. The results provide theoretical support for condition assessment and modification control of converter transformer oil-pressboard insulation.

    2026
    引用
    AI阅读
    加入学术空间
    5Ultrasonic Time–Frequency Feature-Based Estimation of Breakdown Voltage in Thermally Aged Transformer Oil
    Linze Li, Ziwen Huang, Yuan Yao,Wenwen Gu,Qu Zhou

    Transformer oil is a critical insulating and cooling medium in oil-immersed power equipment, and its degradation directly affects insulation reliability and service life. Breakdown voltage is a key indicator of transformer oil dielectric strength; however, conventional measurements are time-consuming and destructive. This study proposes an ultrasonic pulse-echo-based approach for estimating transformer oil breakdown voltage by integrating time–frequency acoustic features with a data-driven regression model. An ultrasonic detection platform was developed, and thermally aged 25# Karamay transformer oil samples were prepared under controlled conditions. A total of 162 time- and frequency-domain features were extracted from ultrasonic echo signals, among which 82 strongly correlated with breakdown voltage were selected using the maximal information coefficient. Based on these features, a support vector regression model optimized by the dung beetle optimization algorithm was established. Experimental results show that the proposed method achieves good estimation accuracy and repeatability against standardized breakdown voltage measurements. This study provides a non-destructive and efficient approach for transformer oil condition assessment, with potential applicability to different oil types through appropriate model training or recalibration using representative data from the corresponding oil. However, the physical mechanisms underlying the correspondence between ultrasonic acoustic features and breakdown voltage remain to be further clarified.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 8559 篇论文

    高被引作者

    作者引用发文
    Gian-Carlo Montanari669685
    Boxue Du6203256
    Shigemitsu Okabe4726142
    George Chen436060
    Yoshimichi Ohki431656
    Shengtao Li392489
    Stanislaw Michal Gubanski359168
    Andrea Cavallini306151
    Len Dissado298740
    Tatsuo Takada294627

    高产作者

    作者引用发文
    Boxue Du6203256
    Shigemitsu Okabe4726142
    Shengtao Li392489
    Gian-Carlo Montanari669685
    Jian Li195284
    Kai Wu199577
    Ju Tang230376
    Xingliang Jiang131275
    Abderrahmane Beroual238174
    Hitoshi Okubo259072

    相关期刊

    IEEE Journal of Photovoltaics
    IEEE Electrical Insulation Magazine
    IEEE Transactions on Magnetics
    Conference on Electrical Insulation and Dielectric Phenomena
    Electrical Insulation Conference
    International Conference on Electrical Materials and Power Equipment
    IEEE International Conference on Dielectrics
    IEEE International Conference on High Voltage Engineering and Application
    IET NANODIELECTRICS
    High Voltage