• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Instrumentation science & technology

    Instrumentation science & technology

    JournalISSN 1073-9149eISSN 1525-6030中科院 工程技术 4区

    年发文量

    研究主题

    论文(1959)

    排序
    1Experimental Performance Characterization of Galvanometer Scanners for High-Resolution Optical Beam Steering in 3D LiDAR Instrumentation
    Fajar Saputra, Septian Arief Widodo,Hari Pratomo,Asep Hapiddin, Mefina Yulias Rofianingrum,Agitta Rianaris,Fikhri Astina Tasmara, Syarifah Raesa Aqila, Ahmad Marzuki,Dwi Hanto

    Optical beam steering is essential for extending the field of view (FoV) in LiDAR systems while maintaining high spatial resolution. However, commercially available galvanometer scanners with similar nominal specifications can exhibit significantly different performance under practical conditions. This study presents a systematic experimental characterization of galvanometer scanners for mechanical beam steering applications. Three scanner models (GVS002, AT-25, and SC-45) were evaluated based on their angular response and scanning speed characteristics, while the proposed effective FoV analysis was demonstrated using the AT-25 scanner under practical LiDAR operating conditions. The comparison between measured and theoretical beam displacement was used to quantify deviation and determine the usable operating range. The effective FoV was defined as the region where the error remains within a specified threshold. The results show that all scanners have similar sensitivities of around 2 degrees/V, with SC-45 being the most sensitive, followed by GVS002 and AT-25. The measured scanning speeds are below 27 kilo points per second (kpps) for all models, enabling fast and stable data acquisition. Effective FoV analysis shows that the practically usable steering range is smaller than the estimated FoV obtained from static angular characterization, particularly at larger steering angles where deviation from the theoretical response increases. Using an error threshold of <= 2%, the experimentally validated effective FoV was found to be smaller than the estimated steering range derived from static characterization. The proposed characterization approach provides a practical basis for evaluating galvanometer scanner performance and supports the development of cost-effective and high-resolution 3D LiDAR beam steering systems.

    2026
    引用
    AI阅读
    加入学术空间
    2Effect of Deformer Geometry on Mechanical Responsiveness of Cylindrical Silicone Rubber Housing for Macrobending Optical Fiber Load Sensor
    H. Pratomo, S. Sulistyo, D. Hanto, B. Widiyatmoko, Q. Qomaruddin, A. Setiono
    2026
    引用
    AI阅读
    加入学术空间
    3Development of a Python-based Photoacoustic Imaging Platform with Automated Instrument Control, Signal Acquisition, and Image Reconstruction
    Donni Kis Apriyanto, Tamado Hendrian Simarmata,Sri Wahyu Suciyati,Gurum Ahmad Pauzi
    2026
    引用
    AI阅读
    加入学术空间
    4High Sensitivity Ultraviolet Light Sensor Based Upon a Fabry-Perot Interferometer and Titanium (IV) Oxide
    Jun Zheng,Chao Jiang, Hangyu Dong, Yuting Feng, Jiajun Liu, Xiushan Liao, Hao Hu,Simei Sun
    2026
    引用
    AI阅读
    加入学术空间
    5Dual-channel Cooperative Matching for Chirp Transform Spectrometry
    Baifan Hu,Mengwei Liu, Lurui Xie, Yuanyuan Hu,Wen Wang,Yining Yin

    In applications such as deep-space exp\loration and atmospheric remote sensing, chirp transform spectrometer (CTS) systems based on surface acoustic wave (SAW) dispersive delay lines have become a key spectral analysis solution owing to their low power consumption, high radiation tolerance, wide bandwidth, and high frequency resolution. However, in dual-channel CTS systems, discrepancies in chirp rate between channels lead to inconsistencies in frequency-to-time (F-T) mapping, which significantly degrade frequency resolution and spectral accuracy. A cooperative chirp-rate matching strategy is presented for a 1 GHz dual-channel CTS system. Based on the proposed strategy, an optimized chirp-parameter selection scheme is developed to improve F-T mapping consistency and the performance of high-resolution spectral measurements. Experimental results demonstrate that the optimized system achieves a frequency resolution of 92.92 kHz with improved spectral performance.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 1959 篇论文

    高被引作者

    作者引用发文
    Haleem J. Issaq4803
    Timothy Veenstra4711
    Thomas P Conrads4711
    Yong Zhao41237
    Qi Wang38938
    Qizhen Shi3452
    Shengli Gao3452
    Neue Uwe D3201
    Zhihong Li30814
    Dane Bicanic25926

    高产作者

    作者引用发文
    Qi Wang38938
    Yong Zhao41237
    Dane Bicanic25926
    Hassan Y Aboul-Enein16722
    Louis Ramaley6617
    Jc Moreno13615
    Marcos Tadeu T. Pacheco16915
    Landulfo Silveira20015
    Zhihong Li30814
    Liliana Giraldo13313

    相关期刊

    Applied spectroscopy
    Vibrational Spectroscopy
    Applied Spectroscopy Reviews
    Plasmonics
    Sensor Review
    Photonic Sensors
    Journal of Spectroscopy
    Spectroscopy Letters
    Journal of Applied Spectroscopy
    Sensing and bio-sensing research