Real-time impedance tracking holds significant potential in optimizing battery management, yet the understanding and practical utilization of dynamic impedance characteristics remain limited. In this research, a dynamic electrochemical impedance spectroscopy (DEIS) measurement protocol based on drifting-voltage suppression is developed to ensure reliable impedance extraction across various charge-discharge profiles. The DEIS measurements are performed on three cells, including a fresh NMC cell, an aged NMC cell, and a fresh LFP cell, at state of charge (SOC) levels of 80%, 50%, and 20%, and temperatures of 35, 25, and 15 °C. The results reveal two distinct dynamic impedance behaviors, which are quantitatively analyzed using the Mahalanobis distance and the coefficient of variation. Moreover, distribution-of-relaxation-time (DRT) analysis is employed to resolve relaxation features and provide qualitative insights into possible electrochemical contributions to the observed load-induced spectral distortions. Practical guidelines are provided for on-board DEIS implementation, real-time state monitoring, and dynamic impedance-based diagnosis.