Electrical Impedance Spectroscopy (EIS) has emerged as a promising non-invasive technique for skin characterization and early detection of dermatological pathologies. However, the reliability and repeatability of EIS measurements are strongly influenced by the electrode-skin interface, particularly by electrode material and geometry. This work presents an experimental evaluation of the variability and repeatability of skin impedance measurements acquired using three different electrode types. Impedance spectra were recorded at three distinct locations on the biceps brachii of a healthy male subject under carefully controlled environmental conditions. For each electrode and measurement site, ten consecutive measurements were performed over a frequency range from 10 Hz to 100 kHz using identical acquisition protocols. Statistical analyses were conducted to assess intra-point repeatability, site-level consistency and inter-electrode variability, including tests for normality, homoscedasticity and non-parametric comparisons. The results showed weak statistically significant differences in the impedance modulus among the electrode configurations, resulting in a significance level of 0.05. These findings highlight the impact of electrode characteristics on measurement dispersion and support the importance of standardized electrode selection in EIS-based skin assessment to improve measurement comparability and reproducibility across experimental setups and future clinical or research-oriented EIS applications.
CANGURO software was developed to complete a workflow to obtain joint and pelvic angles time series as well as derived gait parameters. Original data is obtained from photogrammetry using Cortex 10 system to feed CANGURO software. CANGURO is an original tool developed at the MOVHUM laboratory to support the identification of gait abnormalities and rehabilitation planning. Data processing is based on the result of reviewing key methodological milestones. From the Cortex-10 derived coordinates time series of every segment, CANGURO calculates the heel strike and toe off events, based on the position and acceleration of vertical movement of the heel and toe. CANGURO then calculates the mean gait parameters over 22 strides of self selected walking speed: speed, stride and step lengths, cadence, and swing-to-stride-time duty factor. The clinical report by CANGURO includes also the hip, knee, ankle and foot progression angles time series compered to the selected reference range. CANGURO is multilingual using a central table with one column per language. Finally, representative results from a recorded patient are presented, and future lines of work are discussed. CANGURO is being used to obtain reference values for the population of Uruguay. The first gait parameters obtained for 8 heathy participants are speed $1.21 \mathrm{~m} / \mathrm{s} \pm 0.32$, stride length $127.8 \mathrm{~cm} \pm 18.8$, stride time $1.07 \mathrm{~s} \pm 0.14$, cadence $113.0 \pm 15.0$ step/min, step length $64.2 \mathrm{~cm} \pm 10.0$, step time $0.54 \mathrm{~s} \pm 0.9$, swing time $0.49 \mathrm{~s} \pm 0.08$ and duty factor $45.5 \mathrm{~s} / \mathrm{s} \pm 3.2$. Gait Analysis workflow is limited by the operator interactive time with Cortex 10 to reconstruct all missed markers. Workflow on average takes one hour per patient.
Accurate perforator selection is critical for successful deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. While computed tomography angiography (CTA) provides high-resolution anatomical detail, it lacks functional perfusion assessment. Dynamic infrared thermography (DIRT), in contrast, captures superficial rewarming dynamics but lacks objective anatomical validation. This study presents a standardized multimodal measurement system enabling automated fusion of DIRT with CTA-derived perforator coordinates. The framework integrates controlled thermographic acquisition, realtime hotspot detection, metric spatial calibration, and global one-to-one assignment of thermal hotspots to CTA perforators within a predefined periumbilical region of interest. The workflow was evaluated in 12 patients. Of 46 CTA perforators within the region of interest, 84.8% were successfully linked to thermographic hotspots, with a median spatial offset of 14.74 mm. Automated assignment excluded 76.1% of detected hotspots due to lack of anatomical correspondence, thereby reducing subjective interpretation. The proposed system enables quantitative multimodal validation of functional and anatomical imaging and provides objective support for perforator selection in clinical practice.
Left ventricular elastance is a measure that characterizes the mechanical behaviour of the left ventricle while it pumps blood. Elastance is derived from pressure and volume measurements obtained via invasive catheterization. Non-invasive approaches to study elastance typically involve determining ventricular volume and pressure through imaging techniques such as magnetic resonance imaging or echocardiography or use mathematical models to derive these parameters. In this study, we propose a novel method for non-invasively estimating elastance using measured carotid artery distention data, ejection fraction, cardiac output, and seismocardiogram data. Parameters derived from the sensed outputs are carotid pressure, ventricular volume at the end of systole and diastole, and the timing of left ventricular valves’ opening and closing. These parameters are integrated into the Double Hill function model for computing left ventricular elastance. Using the proposed method, time-varying elastance curves were generated for 20 subjects (9 females and 11 males). Visual analysis of the normalised elastance plots indicates that the shape of the estimated elastance curve aligns well with expected physiological patterns. Additionally, the simulated elastance plots derived from the model exhibit strong beat-to-beat repeatability over 20 cardiac cycles of a single participant.
This paper presents Backpack EKG, a standalone, energy-autonomous three-lead electrocardiography (EKG) platform tailored to decentralized cardiovascular screening in offgrid and resource-limited environments. Unlike long-term ambulatory monitors or diagnostic 12-lead systems, the proposed device targets short-duration, repeatable acquisitions within outreach and first-contact workflows, where electrical infrastructure, connectivity, and external computing devices cannot be assumed. The platform integrates biopotential acquisition, embedded real-time processing, on-device waveform visualization, and fully offline data logging in a robust backpack-deployable form factor. A three-lead configuration is obtained from two measured leads plus a digitally derived lead (Einthoven relation), enabling rhythm inspection and heart-rate estimation while reducing hardware complexity and power demand. Energy autonomy is achieved through a rechargeable lithium-ion battery with photovoltaic-assisted charging, supporting up to 10 h of continuous operation and approximately 120 screening acquisitions per charge. Heart-rate estimation was verified using a calibrated patient simulator across $30-320$ BPM setpoints, achieving a mean absolute error of 0.19 BPM (mean relative error $\lt0.1 \%$) under steady-state conditions. Overall, Backpack EKG provides a measurement-oriented, operationally autonomous acquisition platform for screening campaigns where deployment logistics and power availability constrain conventional EKG instrumentation.