• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Physiological measurement

    Physiological measurement

    JournalISSN 0967-3334eISSN 1361-6579中科院 医学 4区

    年发文量

    研究主题

    论文(4340)

    排序
    1Patient-Referenced and Trajectory Features from Serial ECGs for Haemodynamic Monitoring: an in Silico Study with External Feasibility Analysis
    Yen-Hsiang Wang

    Abstract Objective. Physiological measurements are read against population thresholds, although the within-person change that signals deterioration is smaller than the spread between people. We asked, in simulation, whether serial electrocardiograms read against a patient's own earlier recording carry information about haemodynamic state, and whether the trajectory of that change adds to its current value, in acute haemorrhage. Approach. A nine-dimensional circulatory state-space model generated 600 synthetic subjects in whom haemorrhage reached the waveform only through subject-specific couplings. Results were audited against elapsed time and heart rate, repeated under alternative observation models and with an unknown bleeding onset, and examined in an external feasibility analysis of 77 intraoperative recordings. Main results. Under the generative model, a personal reference raised state discrimination from 0.847 to 0.951 but helped event prediction less than the slope and curvature of the change, which raised five-minute decompensation discrimination from 0.876 to 0.953. Elapsed time, patient characteristics and heart rate reached 0.930 without any electrocardiogram; with onset randomised that shortcut disappeared and the waveform still added +0.084. This division of labour held in all 7 observation models and 24 sampled coupling sets. Intraoperatively, patient-referenced features discriminated concurrent hypotension better (0.683) than absolute features or heart rate, but added nothing distinguishable from zero to the recorded anaesthetic and ventilatory state. Significance. Under the stated assumptions, a personal reference estimates where a patient is and its trajectory where they are going. The external cohort provides preliminary evidence for the portability of the patient-referenced representation but is insufficient to establish clinical performance.

    2026
    引用
    AI阅读
    加入学术空间
    2An Estimation Framework for Cuff-based Blood Pressure Measurement: Analysis and Correction of Systematic Biases
    Masoud Nateghi,Reza Sameni

    Abstract Objective: Modern digital oscillometry and traditional auscultation-based blood pressure (BP) measurement share a similar cuff-based occlusive technique to sense BP: an external arm cuff is inflated above arterial pressure and then deflated while pressure changes due to arterial reopening and pulsation are detected and used to estimate BP. This process introduces inherent biases that can affect clinical assessments. This study models and characterizes these biases and develops an estimation-theoretic framework to mitigate them. Approach: Using the MIMIC database, we examine two major sources of BP measurement error: (1) systematic biases introduced by cuff-based occlusive measurement, and (2) respiratory-driven modulation of BP. Using a model of cuff–artery pressure interaction, we characterize errors in systolic BP (SBP) and diastolic BP (DBP) relative to a-line measurements, and analyze the association between respiration and short-term BP variability. We then evaluate least squares (LS), maximum likelihood (ML), and Bayesian estimators for single and multiple BP measurements using leave-one-subject-out cross-validation. Main Results: Simulated cuff-based measurements underestimated SBP by 9.7±7.8 mmHg and overestimated DBP by 6.6±4.8 mmHg on average. The proposed estimation frameworks substantially improved BP estimation errors in the simulated measurements. LS reduced estimation variability but retained the systematic bias, whereas ML corrected this bias, producing mean errors close to zero. Bayesian estimation further reduced mean absolute error (MAE) for most BP metrics. With three measurements, LS achieved MAEs of 9.7±5.7 mmHg and 6.6±3.6 mmHg for SBP and DBP, respectively, compared with 4.1±4.0 mmHg and 2.8±2.3 mmHg using ML. Bayesian estimation further reduced the MAEs to 3.6±4.4 mmHg and 1.9±2.1 mmHg, respectively. Significance: Cuff-based occlusive BP measurements are subject to inherent systematic biases. Modeling and correcting their systematic measurement errors can improve the accuracy and reliability of cuff-based noninvasive BP estimation, particularly when combined with repeated measurements and prior statistical information.

    2026
    引用
    AI阅读
    加入学术空间
    3Robust Detection of Chagas Disease Via Spatio-Temporal Masked Autoencoder.
    Zi-Jie Zhu, Jing-Ming Zhang, Chen Xia, Shuang Qiu, Jin-Yu Wang, He Li, Xi-Yuan Wang, Xin Xiong, Pan Xia

    OBJECTIVE Chagas disease affects an estimated 6.5 million people in endemic countries, and causes nearly 10,000 deaths annually. Serological testing is effective for diagnosing individual patients, but its limited capacity makes large-scale screening impractical. The electrocardiogram (ECG) provides a low-cost, noninvasive alternative. Our objective is to develop an ECG-based algorithm for the early detection of Chagas disease. APPROACH Firstly, we proposed a novel framework based on the Spatio-Temporal Masked Autoencoder (ST-MAE) to detect Chagas disease from standard 12-lead ECG signals. Secondly, we introduced a two-stage curriculum masking strategy. Thirdly, we introduced a soft label strategy to alleviate the issue of overfitting and handle potential label ambiguity. Fourthly, we incorporated a Gated Attention mechanism into the encoder architecture. MAIN RESULTS As a follow-up entry after PhysioNet/Computing in Cardiology Challenge 2025, our proposed approach achieved a Challenge score of 0.255 on the official hidden test set. SIGNIFICANCE We present a novel framework for the early detection of Chagas disease. We preliminarily verified that our two-stage curriculum masking strategy may enhance the model's ability to capture robust features. The excellent performance suggests that our framework has great potential as an assistive tool for early screening of Chagas disease in high-risk regions.

    2026
    引用
    AI阅读
    加入学术空间
    4Open-source, High-Speed and High-Resolution Data Acquisition Platform for Biopotential Recordings and Neural EIT Applications
    Enrico Ravagli,Alistair McEwan,Kirill Aristovich

    Abstract Objective. Biopotential measurement devices, such as electroencephalography, electrocardiography (ECG), and electromyography (EMG) recorders, are available in low-cost, open-source implementations with standard specifications. However, high-end systems remain expensive and predominantly proprietary, limiting accessibility and customization by research laboratories. In addition, neurophysiology techniques such as bioimpedance-based fast neural electrical impedance tomography (FN-EIT) also rely on these systems for data acquisition. This work aimed to develop an open-source biopotential recording system using off-the-shelf components that achieves performance comparable to high-end devices. Approach. We designed our system to provide simultaneous sampling over 32 channels, 24-bit resolution, 10 kHz bandwidth, 50 kHz sampling rate, and battery-powered operation while reducing cost by two orders of magnitude. System performance was evaluated comparatively against a reference device. Initial validation involved benchtop recordings in saline solution and standard non-invasive biopotential measurements (ECG and EMG). Further in-vivo validation was performed by recording evoked electrophysiological responses and FN-EIT traces from the sciatic nerve of a rat during tibial branch stimulation. Main results. EMG recordings showed comparable RMS peak amplitudes (814 ± 153 µ V vs 897 ± 113 µ V, p = 0.07), while ECG-derived heart rates closely matched between systems (64.8 ± 4.0 bpm vs 65.1 ± 3.1 bpm, p = 0.54). During in-vivo recordings, compound action potentials exhibited comparable amplitudes and morphology (129 ± 26 mV vs 128 ± 25 mV, P = 0.15). FN-EIT recordings showed strongly correlated baseline voltages ( R > 0.93, P = 0.11), sub-microvolt noise levels (0.83 ± 0.36 µ V vs 0.42 ± 0.25 µ V, p < 0.05), and comparable impedance variations (0.006 ± 0.002% vs 0.005 ± 0.003, P > 0.05). FN-EIT images of functional activity recorded with the novel device closely matched reference ones, exhibiting a 98.5% overlap in activated area. Significance. The proposed open-source device has the potential to broaden research access to customizable, high-specification data acquisition hardware and facilitate wider adoption of specialized neural recording techniques such as FN-EIT.

    2026
    引用
    AI阅读
    加入学术空间
    5A Physiology- and Measurement-Informed Framework for Evaluating PPG Features in Cuffless Blood Pressure Estimation
    Myung-Kyu Yi,Jongshill Lee,Jeyeon Lee,In Young Kim

    Abstract Continuous and cuffless blood pressure (BP) estimation using photoplethysmography (PPG) has considerable potential for wearable health monitoring. However, PPG records peripheral optical blood-volume-related changes rather than arterial pressure directly, and its waveform is jointly shaped by systemic hemodynamics, local vascular regulation, sensor–tissue interaction, and measurement conditions. Consequently, high predictive performance does not necessarily establish that a model has learned physiologically valid or mechanism-specific BP information. To address this gap, we propose a physiology- and measurement-informed framework for evaluating PPG-derived descriptors and representations. Rather than treating features as direct measurements of isolated cardiovascular mechanisms, the framework organizes them into four non-exclusive physiological sensitivity domains—cardiac pump-related dynamics, arterial compliance-related dynamics, wave-reflection-related morphology, and peripheral vascular regulation—along with a fifth distinct category for integrative composite representations. Drawing on a qualitative synthesis of 87 studies guided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses, representative descriptors are examined in terms of their directly observed signal properties, candidate physiological sensitivities, mechanism specificity, susceptibility to confounding, calibration dependence, wearable observability, and the evidential basis and limitations of their proposed interpretations. Importantly, the supporting literature provides uneven and often indirect validation of the assumed relationships between peripheral blood-volume-related signals, arterial pressure or flow, and specific hemodynamic mechanisms. Particular attention is given to practical limitations such as heart-rate dependence, temperature, contact pressure, measurement site, and the loss of morphological landmarks in reflective wearable PPG. A brief illustrative audit of a published feature-guided hybrid model is retained as an example of how the framework can distinguish model use of physiologically motivated descriptors from physiological validation. The proposed framework does not establish or validate PPG as a direct or mechanism-specific measure of BP; rather, it organizes the heterogeneous and incompletely validated physiological and measurement assumptions reported in the literature. It provides a structured basis for identifying conditions under which BP-related information may be observable and for defining stronger validation requirements for cuffless BP estimation systems.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 4340 篇论文

    高被引作者

    作者引用发文
    John Allen821936
    John J. B. Allen61501
    Gari Clifford502863
    Andy Adler325352
    David S Holder282764
    Frerichs Inéz263156
    Richard Bayford262064
    Chengyu Liu235928
    Nigel Lovell213526
    Roman Hovorka19642

    高产作者

    作者引用发文
    Richard Bayford262064
    David S Holder282764
    Gari Clifford502863
    Frerichs Inéz263156
    Andy Adler325352
    Alan Murray163041
    Alberto Porta86237
    John Allen821936
    B. H. Brown170135
    Joachim Behar183735

    相关期刊

    Medical Measurements and Applications
    IEEE reviews in biomedical engineering
    Journal of mechanics in medicine and biology
    Computing in cardiology
    IEEE journal of translational engineering in health and medicine
    International Conference on Wearable and Implantable Body Sensor Networks
    IEEE Transactions on Biomedical Engineering
    International Conference of the IEEE Engineering in Medicine and Biology Society
    IEEE Open Journal of Engineering in Medicine and Biology
    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference