Wheel-spoke cable-truss structures are widely used in large-span stadiums because of their high structural efficiency and lightweight form. Due to their geometric flexibility and force-shape coupling, the construction process and structural performance after formation require systematic investigation. In this study, a combined experimental and numerical investigation was performed on the roof of a 60,000-seat professional football stadium. A cable construction method based on integral traction lifting and staged tensioning and anchoring of radial cables was proposed. A 1:20-scale model was developed based on the similarity relationships. Static loading, dynamic response, and construction-stage tests were then conducted, and the measured results were compared with numerical predictions. The results show that the cable-force and nodal-displacement relationships between the scaled model and the prototype agree well with the established similarity relationships. Construction-stage tests demonstrate that the proposed erection method results in a progressive structural development with a smooth and uniform evolution of cable forces. The measured cable forces remain below the cable bearing capacity throughout the process. In addition, the radial sliding displacements of the ring-truss support nodes remain in a reasonable range. The study combines test and simulation results to provide a theoretical foundation and construction guidance for the widespread application of wheel-spoke cable-truss structures.
Concrete-filled aluminum alloy tubes (CFAT) combine the advantages of aluminum alloys and conventional concrete-filled steel tubes (CFST), and therefore exhibit promising potential applications in engineering structures in corrosive environment. However, existing studies on the axial compressive behavior of CFAT columns remain limited, and corresponding design methods and standard provisions are still scarce. Against the above backgrounds, finite element analysis (FEA) models of CFAT columns with square cross-sections under the axial loading are firstly introduced; supplementary axial compression tests on CFAT columns with square cross-sections are then conducted, and together with existing experimental data, are used to validate the rationality and accuracy of the FEA model. Based on the validated FEA models, the working mechanism of CFAT columns with square cross-sections is deeply explored by comparisons with that of CFST columns, and the underlying differences in their behavior are clarified. Furthermore, the influences of cross-sectional dimensions, confinement factor, concrete strength, and nominal yield strength of the aluminum alloy tube on the load-bearing capacity and failure mechanisms of CFAT columns with square cross-sections are systematically investigated. Based on the results of the parametric analysis, curve-fitted formulas for the axial load-bearing capacity and corresponding ultimate strain of CFAT stub columns with square cross-sections are proposed. The findings of this study can provide useful references for the structural design and practical application of CFAT columns.
This study investigated the influence of shear studs on the interfacial bond behavior between shaped steel and Engineered Cementitious Composites (ECC) through push-out tests and Digital Image Cor-relation (DIC) technology. A total of eight shaped steel-ECC short column specimens (seven with shear studs and one relying solely on natural bond) were tested. The experimental program evaluated the effects of shear stud presence, ECC compressive strength, fiber volume content, and ECC cover thick-ness on failure modes, surface strain distribution, bond stress-slip behavior, and characteristic bond strengths. The results indicated that specimens equipped with shear studs developed multiple fine cracks at both ends along with penetrating longitudinal cracks, whereas the natural bond specimen exhibited only two cracks at the loaded end. Furthermore, shear stud-equipped specimens displayed multi-peak wavelike strain distributions propagating from the loaded end to the free end, attributed to sequential activation of the studs. In contrast, the natural bond specimen showed strain localization near the loaded end. The shear stud-equipped specimens primarily resisted progressive interfacial slip through shear stud deformation, thereby delaying the transmission of interfacial shear stress. Com-pared with the natural bond specimen, the initial, ultimate, and residual bond strengths of the stud-equipped specimens increased by 81.08%, 81.75%, and 103.64%, respectively. Finally, a calculation formula for the ultimate bond strength was developed, accounting for the combined contributions of the natural bond and the shear studs.
Under solar radiation, steel box girders generate varying temperature stresses and deformations, affecting construction and operation. Accurate calculation of the temperature distribution in steel box girders is a prerequisite for analyzing these temperature effects. Steel box girders can exist in two states during the construction and operation stages: chamber-open and chamber-closed. However, current studies do not differentiate the temperature distribution between these two forms, leading to significant errors observed in practical engineering. This study conducted on-site measurements and finite element analysis on both chamber-open and chamber-closed steel box girders to investigate the actual temperature gradient of steel box girders. Obtained temperature distributions for both states and proposed methods for calculating transverse and vertical temperature gradients while analyzing factors influencing the temperature of steel box girders. The study found that there are temperature gradients along the transverse and vertical directions of the steel box girders, while the longitudinal temperature is uniform. The transverse temperature gradients of the top plate of open and closed steel box girders are calculated using second and third-level steps, respectively. The vertical temperature gradient in closed and opened sections is divided into two segments along the height with a boundary at 600mm from the top plate. Additionally, wind speed, solar radiation, and surface coating can influen the temperature gradient of the steel box girders. In this study, the accuracy of the calculation method was also verified using measured data. For the two cases of chamber-open and chamber-closed steel box girders, the R2 of the measured data and the predicted data are 0.99 and 0.98, respectively, which meet the requirements of engineering accuracy.
In large-span continuous composite girder bridges with corrugated steel webs (CSWs), two measures are commonly employed near intermediate supports to enhance shear resistance: encasing the thin CSWs with concrete to form a composite web and installing external prestressing tendons. However, existing research has primarily examined these measures in isolation, resulting in a limited understanding of their synergistic effects on shear performance. Through finite element simulation, experimental validation and theoretical analysis, this study investigates shear behavior of concrete-encased tapered girders with CSWs under external prestressing. The findings demonstrate that traditional shear design methods, which are based on the analysis of prismatic girders, typically consider only the vertical component of external prestressing when evaluating its influence on shear behavior and assume that the web resists the entire resulting shear force. While this assumption is generally applicable to prismatic girders with horizontal flanges, it becomes limited in tapered girders because the prestressing-induced bending moment and horizontal axial force can generate self-equilibrating additional shear forces between the concrete-encased web and the inclined bottom flange. This phenomenon, termed the Resal effect, leads to a significant redistribution of internal shear forces within the structure. Parametric analyses reveal that the Resal effect intensifies with larger bottom flange inclination and near the free end, where the actual web shear force can nearly double the traditionally predicted value, with a maximum underestimation of 42.34%. To address this, a unified theoretical model incorporating the Resal effect is proposed. The model accurately predicts shear redistribution and restricts the maximum prediction error to within 15.62%, providing a reliable design method for both prismatic and tapered composite girders.