With the increasing emphasis on green and low-carbon initiatives, electric aircraft have become a focal point in the aviation industry. To investigate the air discharge mechanisms of onboard equipment under high-frequency voltage, this study analyzes the air discharge phenomena in a needle-plate gap under pulsed electric fields in high-altitude environments. The research considers factors such as temperature and air pressure at different altitudes, pulsed electric field parameters, and humidity. A simulation model of needle-plate electrode streamer discharge was constructed, and an experimental platform was developed for qualitative analysis. The results indicate that the streamer discharge characteristics obtained from simulations and experiments are highly consistent under variations in altitude, pulsed electric field parameters, and humidity. When the reduced field strength remains constant, the breakdown voltage values at different altitudes were quantitatively calculated. In addition, the effects of altitude, pulsed electric field parameters, and humidity on streamer discharge characteristics were studied. Furthermore, the study explains the underlying reasons for variations in electron density, electric field intensity distribution, and streamer development speed under different conditions.
The rise and fall of the internal temperature of power transformer will cause the moisture to change its distribution and aggregation position, and the local high moisture content will seriously affect the electrical strength of oil-paper insulation. Therefore, it is necessary to study the adsorption and desorption of moisture in cellulose insulation at different temperatures. In this paper, three oil-cellulose mixed systems (OCS) of 105 atoms with different moisture contents were established by molecular dynamics method, and temperature rise and temperature drop simulations were conducted respectively. The changes of the water molecule number (NW) in the interface domain and oil domain were obtained. By analyzing the solvent accessible surface area (SASA) and the microscopic scanning electron microscope (SEM) images of cellulose insulation, the effect of temperature changes and the deterioration of cellulose molecules on the moisture adsorption and desorption in cellulose insulation were studied. The results show that after the high-temperature system is reversely cooled, water molecules in the oil domain will migrate rapidly to the cellulose domain, while the irreversible deterioration of cellulose after high temperature leads to the weakening of its adsorption capacity. As a result, a large amount of water is retained at the interface. For the simulation of temperature rise, the higher the temperature is, the more water molecules accumulate in the oil domain and interface domain, and the stronger the desorption effect of cellulose on moisture. Notably, NW in the interface domain is not a simple increment trend, but an oscillatory increase and decrease trend that decreases first and then increases. The higher the temperature is, the more obvious the trend is. The research results have important theoretical value for the real-time monitoring of moisture in oil-immersed power equipment and the evaluation of its insulation performance
Abstract Due to the limitations imposed by urban power grid outages for maintenance, on‐line harmonic current detection technology for distribution network cables is expected to become an effective supplement to traditional offline diagnostic methods, enhancing the real‐time diagnosis of distribution network cable insulation conditions. This study established a 10 kV distribution network cable test platform and prepared typical defective cables subjected to moisture and long‐term thermal aging. Using COMSOL finite element electromagnetic simulation, the magnetic flux evolution laws of the cable insulation under typical defects were obtained. Experimental tests provided the harmonic current characteristics and statistical features of cables with typical defects. Based on these data, a method for analysing the degradation degree of distribution network cables was constructed using least absolute shrinkage and selection operator (LASSO) regression analysis. Furthermore, a defect‐type identification method based on cluster analysis was proposed. Results indicate that the odd harmonics and the 4th harmonic of the distribution network cable's harmonic current are closely related to the cable's degradation state. A model integrating principal component analysis (PCA) data dimensionality reduction and expectation‐maximization clustering analysis achieved a recognition accuracy of up to 75.64% in distinguishing between moisture‐affected and normal cable states. The proposed on‐line detection and evaluation methods can effectively identify high‐risk cables with latent defects.
An interleaved high step-up boost-zeta converter with resonant coupled inductors voltage multiplier cell is proposed in this article. The proposed converter achieves very high voltage gain by integrating the boost converter and the zeta converter and using coupled inductor voltage multiplier technique. Meanwhile, low input current ripple and continuous output current are realized, which is beneficial for photovoltaic, fuel cell, and dc-bus. Moreover, the zero-voltage switching (ZVS) and low voltage stress of the switches are achieved by utilizing the active clamp circuits. With the resonance between the leakage inductance and the resonant capacitor in the resonant coupled inductor multiplier cell, the zero-current switching (ZCS) of the diodes are achieved, leading to low reverse recovery losses. In addition, the main switches of the proposed converter can be operated in the full duty cycle range, which achieves a wide range of step-up regulation. The operation principles and steady-state performance of the proposed converter are analyzed in detail. A 400 W prototype with 30-40 V input, 400 V output is built to verify the theoretical analysis.
Gallium nitride high-electron-mobility transistor (GaN HEMT) power devices are favored in various scenarios due to their high-power density and efficiency. However, with the significant increase in the heat flux density, the junction temperature of GaN HEMT has become a crucial factor in device reliability. Since the junction temperature monitoring technology for GaN HEMT based on temperature-sensitive electrical parameters (TSEPs) is still in the exploratory stage, the TSEPs' characteristics of GaN HEMT have not been definitively established. In this paper, for the common steady-state TSEPs of GaN HEMT, the variation rules of the saturation voltage with low current injection, threshold voltage, and body-like diode voltage drop with temperature are investigated. The influences on the three TSEPs' characteristics are considered, and their stability is discussed. Through experimental comparison, it is found that the saturation voltage with low current injection retains favorable temperature-sensitive characteristics, which has potential application value in junction temperature measurement. However, the threshold voltage as a TSEP for certain GaN HEMT is not ideal in terms of linearity and stability.