The aim of the 'BioQuaRT' (Biologically weighted Quantities in RadioTherapy) project is to develop measurement techniques for characterising charged particle track structure on different length scales, and to correlate at the cellular level the track structure properties with the biological effects of radiation. This multi-scale approach will allow characterisation of the radiation qualities used in radiotherapy and the related biological effects. Charged-particle microbeam facilities were chosen as the platforms for all radiobiology experiments in the 'BioQuaRT' project, because they allow targeting single cells (or compartments of a cell) with a predefined number of ionising particles and correlating the cell-by-cell induced damage with type and energy of the radiation and with the number of ions per cell. Within this project, a novel in situ protocol was developed for the analysis of the misrepaired and/or unrepaired chromosome damage induced by charged-particle irradiations at the Physikalisch-Technische Bundesanstalt (PTB) ion microbeam facility. Among the cytogenetic biomarkers to detect and estimate radiation-induced DNA damage in radiobiology, chromosomal aberrations and micronuclei were chosen. The characteristics of the PTB irradiation system required the design of a special in situ assay: specific irradiation dishes with a base made from a biofoil 25-µm thick and only 3000-4000 cells seeded and irradiated per dish. This method was developed on Chinese hamster ovary (CHO) cells, one of the most commonly used cell lines in radiobiology in vitro experiments. The present protocol allows the simultaneous scoring of chromosome aberrations and micronuclei on the same irradiated dish. Thanks to its versatility, this method could also be extended to other radiobiological applications besides the single-ion microbeam irradiations.
Dosimetric measurements in the field of secondary cosmic radiation were extensively made during the last years. Since the majority of these measurements were performed on-board passenger aircraft at altitudes between 10 and 12 km, measurements at higher altitudes are desirable for the verification of the legal dose assessment procedures for aircrew. A simple solution is to use a high-altitude balloon that reaches altitudes as high as 30 km. In this work, it is shown that the dose rate profile up to 30 km can be measured with acceptable uncertainties using a Si-detector.
The NAVIgation DOsimetry System (NAVIDOS) comprises a complete readout system for a radiation detector, an air pressure sensor and a GPS receiver.The detector system DOSTEL uses silicon detectors which make NAVI-DOS light weighted and compact in size.Therefore, NAVI-DOS is well suited to be installed on board aircraft.The calibration of NAVIDOS in terms of ambient dose equivalent is done by an in-field comparison with the PTB reference instrument πDOS.We also show that the dependence of these results on the vertical cut-off rigidity can be explained by the low response of the silicon detectors for neutrons.Therefore, in-flight measurements have been performed together with the PTB reference instrument πDOS.The dose rates, calculated using the PTB code FDOScalc, were verified with these πDOS measurements.The calibration of NAVIDOS was done with FDOScalc and results in calibration factors between 3.4 in the polar and 2.4 in the equator region.
In an inter-disciplinary collaboration of Physikalisch-Technische Bundesanstalt (PTB), German Collection of Microorganisms and Cell Cultures (DSMZ) and Heinrich-Heine University, live-cell imaging has been established at the charged-particle microbeam facility of PTB. Candidate genes participating in DNA strand-break repair pathways such as PARP-1, MRE11, MSH2, MDC1 and p53BP1 have been modified to generate fluorescent fusion proteins. Using multi-cistronic expression vectors, stable genomic integration was achieved in HT-1080 fibroblasts. The aim of this study is to characterise and use these highly reliable cell lines for studying initial steps of DNA damage responses and kinetics of repair after microbeam irradiation with high- and low-linear energy transfer (LET) particles in living cells at physiological conditions.
Intercomparisons of dosemeters used in radiation protection are performed routinely in reference radiation fields under well-defined conditions. In the case of the radiation protection of aircrew members, such reference fields either do not exist or they can be partially simulated by accelerator-based fields. Another method is to perform simultaneous measurements on board an aircraft under constant flight conditions, i.e. at defined latitude, longitude and altitude. The intercomparison presented in this work is the second one of its kind. As reference instruments, two types of tissue-equivalent proportional counters (TEPC) were used in comparison with different silicon detector systems. The excellent agreement of the FDOScalc code, which is based on measurements made by PTB during different phases of solar cycle 23 with the TEPC measurements and the results of the preceding project "Coordinated Access to Aircraft for Transnational Environmental Research" (CAATER) even allows the in-field calibration of the Si dosemeters.
The photon contribution to ambient dose equivalent in several wide-spectrum reference neutrons fields of the Institute for Radiological Protection and Nuclear Safety were measured using a Geiger-Müller counter. For the investigated fields, the ratio of photon to neutron ambient dose equivalent ranged between 0.03 and 0.20. The results show that the Geiger-Müller tube is a versatile instrument for dosimetry in mixed photon-neutron fields if sufficient information for the calculation of corrections is available.
The PTB microbeam is routinely used for the irradiation of living cells using protons (1-20 MeV) and alpha particles (1-28 MeV). The beam diameter is approximately 2 microm (fwhm), achieved by focussing, resulting in an excellent energy resolution and practically no scattered particles. Recently, an electrostatic beam scanner was added to the facility which allows targeting of each cell within 1 ms. This and other improvements led to an increase in the experimental speed of the system to a maximum of 50,000 cells per hour including all experimental steps. To improve the versatility of the facility further, a module for automatic quantification of immunocytochemical staining was implemented. This allows the analysis of protein activation, taking into account the positional information of the irradiation run.
A very promising method to measure the ambient dose equivalent H*(10) at flight altitudes is to use Tissue Equivalent Proportional Counters (TEPC). The measured quantity is the lineal energy, y, which can be converted into equivalent dose as a good estimate of H*(10). According to the lineal energy transfer (LET) spectra one may even extract information about the composition of the radiation field. A new system was developed by adding a surrounding coincidence detector (CACS: Coincidence/Anti-Coincidence Shield) that allows one to identify the primary particle, which deposits energy in the TEPC, as neutral or charged. The entire system was calibrated in the neutron and high-energy photon reference fields at PTB. One of the results of these measurements is, the use of low- and high-LET calibration factors when performing measurements in mixed radiation fields. The TEPC/CACS system is now operated on-board aircrafts as a fixed or mobile dosimetry system.