Magnetic resonance imaging (MRI) is a cornerstone of neurological care, serving as the gold standard for diagnosing pathologies, such as brain tumors and, together with computed tomography, stroke. However, the high capital costs, specialized infrastructure requirements such as expensive and bulky radiofrequency-shielding cages, and the operational complexity of conventional high-field scanners (1.5T and 3T) largely confine MRI to centralized imaging facilities. This scenario often leads to reliance on brain computed tomography or ultrasound in point-of-care settings, despite MRI's superior soft-tissue contrast for diagnosis and prognosis. In the past decade, there has been renewed interest in compact and simplified ultra-low-field (under 0.1T) MRI scanners, fueled by advances in engineering and computing. Here, we review the recent developments in ultra-low-field brain MRI, which enable imaging in open environments and demonstrate initial clinical applicability in point-of-care settings. We also envision future developments along 3 focus areas (ie, hardware, imaging protocols, and data-driven image formation and analysis) to address the current limitations of image quality and contrast in ultra-low-field brain MRI systems.
BACKGROUND AND PURPOSE: Complicated American Heart Association (AHA) lesion type VI plaques and cCAPs, characterized by the presence of intraplaque hemorrhage and a surface defect or thrombus, are strongly associated with ischemic stroke and stroke recurrence. Hemodynamics seem to play a relevant role in their development. Thus, we investigated the association of 4D-flow MRI-derived local wall shear stress (WSS) and the oscillatory shear index (OSI) with the presence of cCAPs in patients with mild-to-moderate ICA stenosis. MATERIALS AND METHODS: From a prospective and consecutive cross-sectional study with 121 patients with high cardiovascular risk, 39 patients (49 carotid arteries) demonstrated a 10%-50% ICA stenosis and were included in this analysis. Plaque composition was determined according to the modified AHA classification of lesions by high-resolution multicontrast 3T MRI. We determined WSS (minimum, mean, and maximum) and the OSI in vivo by 4D-flow MRI at different locations within the stenosis (upstream, stenosis center, and downstream). We studied the association of each hemodynamic parameter with the presence cCAPs by logistic regression analysis adjusted for age, sex and plaque thickness. RESULTS: Eleven (22.4%) of the 49 cases of ICA stenosis in our cohort showed cCAP. WSS and OSI at the beginning of the stenosis did not differ between complicated and stable plaques. By contrast, WSS was significantly higher in the stenosis center and poststenotic region in cCAPs. OSI was significantly higher in the stenosis center of stable plaques. Logistic regression analysis revealed a significant association for WSSmean (OR per SD increase, 1.97; 95% CI, 1.14-3.39, P = .015) and for WSSmaximum (OR per SD increase, 1.84; 95% CI, 1.10-3.08, P = .020), but not for WSSminimum and OSI with the presence of cCAPs. CONCLUSIONS: Higher WSS in ICA stenosis was significantly associated with the presence of cCAPs, underlining the potential role of hemodynamics in their development.
Physiological brain pulsations play a critical role in sleep physiology, but their underlying mechanisms remain poorly understood. To study these pulsations more deeply, we employed ultrafast magnetic resonance encephalography (MREG) to capture complex-valued 4D fMRI brain data at a critical 10 Hz sampling rate in healthy volunteers during wakefulness and sleep. We compared the phase and magnitude components of the MREG signal, as the phase component is known to be particularly sensitive to subtle flow and susceptibility changes, offering insights beyond magnitude-only analysis. This approach enabled whole-brain mapping of the amplitudes of all three physiological pulsations - very low frequency (VLF), cardiac, and respiratory - using an extended amplitude of low frequency fluctuation (ALFF) method. We identified significant increases in respiratory amplitudes during sleep compared to wakefulness in both phase and magnitude signals, while the VLF and cardiac phase amplitudes did not show significant differences. Phase respiration map showed increase especially in default mode network regions, while additional patterns were observed in the cerebellum, ventricles, cerebral aqueduct, and subarachnoid cisterns. In contrast, the magnitude maps showed increased amplitudes more widespread across the cerebrum. These findings highlight the complementary nature of phase and magnitude data in fMRI and suggest that combining these signals provides a more comprehensive understanding of brain physiological dynamics during sleep than conventional magnitude-only analyses.
Prior research suggests that cognitive control, indicated by NoGo N2 amplitudes in Go/NoGo tasks, is associated with dispositional anxiety. This negative association tends to be reduced in anxiety-enhancing experimental conditions. However, anxiety-reducing conditions have not yet been investigated systematically. Thus, the present study compares the effect of a relaxation instruction with the conventional speed/accuracy instruction in a Go/NoGo task on the correlation of the NoGo N2 with two subconstructs of dispositional anxiety, namely anxious apprehension and anxious arousal. As the test of differences between correlations needs considerable statistical power, the present study was included into the multi-lab CoScience Project. The hypotheses, manipulation checks, and the main path of pre-processing and statistical analysis were preregistered. Complete data sets of 777 participants were available for data analysis. Preregistered general linear models revealed that the different instructions of the task (speed/accuracy vs. relaxation) had no effect on the association between dispositional anxiety and the NoGo N2 amplitude in general. This result was supported by Cooperative-Forking-Path analysis. In contrast, a preregistered latent growth model with categorical variables revealed that anxious arousal was a negative predictor of the NoGo N2 intercept and a positive predictor of the NoGo N2 slope. Non-preregistered growth models, allowing for correlations of anxious apprehension with anxious arousal, revealed that higher anxious apprehension scores were associated with more negative NoGo N2 amplitudes with increased relaxation. Results are discussed in the context of the compensatory error monitoring hypothesis and the revised Reinforcement Sensitivity Theory.
Frontal alpha asymmetry has been proposed as a ubiquitous marker of state and trait approach motivation, but recent meta-analyses found weak or nonexistent links with personality traits. It has been suggested that frontal asymmetry may show stronger individual differences in situations that elicit approach motivation (state-trait interaction). To investigate this with sufficient statistical power, we utilized data from the CoScience project (N = 740). Frontal asymmetry was measured during a resting period, a picture viewing task, and a guessing task, which were expected to trigger different levels of approach motivation. Results showed that frontal asymmetry was not reliably affected by task manipulations and did not relate to self-reported traits. Furthermore, Bayesian statistics and a cooperative forking path analysis were used to supplement the preregistered analyses. To conclude, this comprehensive analysis could not support the validity of frontal asymmetry as a marker of approach motivation, neither as a reliable state nor as a trait marker.
BackgroundAs outlined by the dual control model (DCM), individual differences in the regulation of sexual arousal following sexual stimulation depend on two distinct neurophysiological processes: sexual excitation (SE) and sexual inhibition (SI). Although associations with sexual function, behavior, and cue processing have been demonstrated in previous research, underlying neural correlates remain insufficiently explored. Moreover, interactive effects of SE/SI as proposed by the DCM, as well as factors impacting SE/SI properties, such as the use of oral contraceptives (OCs), have not received adequate attention in existing research.Methods90 healthy, sexually active women (n = 51 using OCs, n = 39 naturally cycling) completed an Emotional-Picture-Stroop-Paradigm (EPSP) while a 64-channel EEG was recorded. LPP amplitudes toward erotic and neutral stimuli were consecutively computed as a marker of motivational salience and approach motivation. Additionally, women provided self-reports of SE/SI and sexual function. Moderation analyses were performed to assess interactive effects of SE/SI in predicting LPP amplitudes and sexual function.ResultsSexual function was negatively associated with SI levels but unrelated to SE. Higher SI was associated with reduced LPP amplitudes in response to erotic stimuli. This negative association was, however, attenuated for women high in SE, suggesting interactive effects of SE/SI. Furthermore, women using OCs reported lower SE compared to naturally cycling women.ConclusionThe observed findings provide additional psychophysiological evidence supporting the DCM and underscore the relevance of interactive SE/SI effects in stimulus processing and approach motivation. They also highlight the possible impact of OCs on psychosexual variables that warrants further research.
Multiple sites within Germany operate human MRI systems with magnetic fields either at 7 Tesla or 9.4 Tesla. In 2013, these sites formed a network to facilitate and harmonize the research being conducted at the different sites and make this technology available to a larger community of researchers and clinicians not only within Germany, but also worldwide. The German Ultrahigh Field Imaging (GUFI) network has defined a strategic goal to establish a 14 Tesla whole-body human MRI system as a national research resource in Germany as the next progression in magnetic field strength. This paper summarizes the history of this initiative, the current status, the motivation for pursuing MR imaging and spectroscopy at such a high magnetic field strength, and the technical and funding challenges involved. It focuses on the scientific and science policy process from the perspective in Germany, and is not intended to be a comprehensive systematic review of the benefits and technical challenges of higher field strengths.
MREG allows very fast measurement of physiological signal changes at 100 ms acquisition time per volume. In order to investigate BOLD and non-BOLD contributions to the observed signal variations we have implemented an interleaved measurement scheme based on signal readout with two different echo times (15 and 36 ms). The interleaved implementation with alternating echo times increases the acquisition time to 200 ms, which still allows to investigate BOLD vs. non-BOLD signal changes at frequencies up to ±2.5 Hz. Preliminary measurements demonstrate the feasibility of ME-MREG in detecting both neuronal activations and resting-state functional connectivities.
In March 2022, the first ISMRM Workshop on Low-Field MRI was held virtually. The goals of this workshop were to discuss recent low field MRI technology including hardware and software developments, novel methodology, new contrast mechanisms, as well as the clinical translation and dissemination of these systems. The virtual Workshop was attended by 368 registrants from 24 countries, and included 34 invited talks, 100 abstract presentations, 2 panel discussions, and 2 live scanner demonstrations. Here, we report on the scientific content of the Workshop and identify the key themes that emerged. The subject matter of the Workshop reflected the ongoing developments of low-field MRI as an accessible imaging modality that may expand the usage of MRI through cost reduction, portability, and ease of installation. Many talks in this Workshop addressed the use of computational power, efficient acquisitions, and contemporary hardware to overcome the SNR limitations associated with low field strength. Participants discussed the selection of appropriate clinical applications that leverage the unique capabilities of low-field MRI within traditional radiology practices, other point-of-care settings, and the broader community. The notion of "image quality" versus "information content" was also discussed, as images from low-field portable systems that are purpose-built for clinical decision-making may not replicate the current standard of clinical imaging. Speakers also described technical challenges and infrastructure challenges related to portability and widespread dissemination, and speculated about future directions for the field to improve the technology and establish clinical value.
The paper describes the evolution of low-field MRI from the very early pioneering days in the late 70 s until today. It is not meant to give a comprehensive historical account of the development of MRI, but rather to highlight the different research environments then and now. In the early 90 s, when low-field systems below 1.5 T essentially vanished, there were just no reasonable means available to make up for the factor of roughly three in signal-to-noise-ratio (SNR) between 0.5 and 1.5 T. This has drastically changed. Improvements in hardware-closed Helium-free magnets, RF receiver systems and especially much faster gradients, much more flexible sampling schemes including parallel imaging and compressed sensing and especially the use of AI at all stages of the imaging process have made low-field MRI a clinically viable supplement to conventional MRI. Ultralow-field MRI with magnets around 0.05 T are also back and constitute a bold and courageous endeavor to bring MRI to communities, which have neither the means nor the infrastructure to sustain a current standard of care MRI.
Despite a plethora of research, associations between individual differences in personality and electroencephalogram (EEG) parameters remain poorly understood due to concerns of low replicability and insufficiently powered data analyses due to relatively small effect sizes. The present article describes how a multi-laboratory team of EEG-personality researchers aims to alleviate this unsatisfactory status quo. In particular, the present article outlines the design and methodology of the project, provides a detailed overview of the resulting large-scale dataset that is available for use by future collaborators, and forms the basis for consistency and depth to the methodology of all resulting empirical articles. Through this article, we aim to inform researchers in the field of Personality Neuroscience of the freely available dataset. Furthermore, we assume that researchers will generally benefit from this detailed example of the implementation of cooperative forking paths analysis.
Over the years the development of field strength in magnetic resonance imaging (MRI) has continued to increase from the low-field systems in the early years (0.2-0.5 T) to 1.5 T to 3 T to 7 T and more. In the last 2 years, there has been a renewed interest in MRI at lower fields, mainly driven by the development of "dry" superconductive magnets. The following article demonstrates that this renewed interest for lower fields is not a deja vu purely driven by economic needs. The field strength appears to be from yesterday, but the combination with the tremendous improvements and innovations of all relevant components-gradients, radiofrequency system and especially new algorithms including the use of artificial intelligence (AI)-allow the realization of diagnostically adequate MRI without compromise in patient throughput and efficiency. In addition to the lower field, there are also some inherent advantages, e.g., for MRI of the lung and of metallic implants and especially for interventional MRI. It has already been shown that many of the devices used for interventional procedures (catheters, biopsy needles) can be used at lower fields without costly modifications. In addition, low-field MRI also allows the robust use of highly efficient sampling methods like spiral MRI. It is therefore safe to predict that low-field MRI is not only a cost-efficient compromise, but has the potential to open up new fields of application.
Background: Aortic stiffness is associated with a higher incidence of cardiovascular events including stroke. The primary aim of this study was to evaluate whether increased pulse wave velocity (PWV), a marker of stiffness, is an independent predictor of aortic atheroma. The secondary aim was to test whether increased PWV reinforces retrograde blood flow from the descending aorta (DAo), a mechanism of stroke. Methods: We performed a cross-sectional case-control study with prospective data acquisition. In all, 40 stroke and 60 ophthalmic patients matched for age and cardiovascular risk factors were included. Multicontrast magnetic resonance imaging (MRI) protocol of the aorta tailored to allow a detailed plaque analysis using 3-dimensional (D) T1-weighted bright blood, T2-weighted and proton density-weighted black blood, and hemodynamic assessment using 4D flow MRI was applied. Individual PWV was calculated based on 4D flow MRI data using the time-to-foot of the blood flow waveform. The extent of maximum retrograde blood flow from the proximal DAo into the arch was quantified. Results: PWV was higher in stroke patients compared with controls (7.62 +/- 2.59 vs. 5.96 +/- 2.49 m/s; P=0.005) and in patients with plaques (irrespective of thickness) compared with patients without plaques (7.47 +/- 2.89 vs. 5.62 +/- 1.89 m/s; P=0.002). Increased PWV was an independent predictor of plaque prevalence and contributed significantly to a predictor model explaining 36.5% (Nagelkerke R2) of the variance in plaque presence. Maximum retrograde flow extent from the proximal DAo was not correlated with PWV. Conclusions: Aortic stiffness was higher in stroke patients and associated with a higher prevalence of plaques. Increased PWV was an independent predictor of plaque presence. Accordingly, regional PWV seems to be a valuable biomarker for the assessment and management of aortic atherosclerosis. However, no association was found for increased retrograde flow extent from the DAo.
Background Three‐dimensional (3D) multiecho balanced steady‐state free precession (ME‐bSSFP) has previously been demonstrated in preclinical hyperpolarized (HP) 13 C‐MRI in vivo experiments, and it may be suitable for clinical metabolic imaging of prostate cancer (PCa). Purpose To validate a signal simulation framework for the use of sequence parameter optimization. To demonstrate the feasibility of ME‐bSSFP for HP 13 C‐MRI in patients. To evaluate the metabolism in PCa measured by ME‐bSSFP. Study Type Retrospective single‐center cohort study. Phantoms/Population Phantoms containing aqueous solutions of [1‐ 13 C] lactate (2.3 M) and [ 13 C] urea (8 M). Eight patients (mean age 67 ± 6 years) with biopsy‐confirmed Gleason 3 + 4 ( n = 7) and 4 + 3 ( n = 1) PCa. Field Strength/Sequences 1 H MRI at 3 T with T 2 ‐weighted turbo spin‐echo sequence used for spatial localization and spoiled dual gradient‐echo sequence used for B 0 ‐field measurement. ME‐bSSFP sequence for 13 C MR spectroscopic imaging with retrospective multipoint IDEAL metabolite separation. Assessment The primary endpoint was the analysis of pyruvate‐to‐lactate conversion in PCa and healthy prostate regions of interest (ROIs) using model‐free area under the curve (AUC) ratios and a one‐directional kinetic model ( k P ). The secondary objectives were to investigate the correlation between simulated and experimental ME‐bSSFP metabolite signals for HP 13 C‐MRI parameter optimization. Statistical Tests Pearson correlation coefficients with 95% confidence intervals and paired t ‐tests. The level of statistical significance was set at P < 0.05. Results Strong correlations between simulated and empirical ME‐bSSFP signals were found ( r > 0.96). Therefore, the simulation framework was used for sequence optimization. Whole prostate metabolic HP 13 C‐MRI, observing the conversion of pyruvate into lactate, with a temporal resolution of 6 seconds was demonstrated using ME‐bSSFP. Both assessed metrics resulted in significant differences between PCa (mean ± SD) (AUC = 0.33 ± 012, k P = 0.038 ± 0.014) and healthy (AUC = 0.15 ± 0.10, k P = 0.011 ± 0.007) ROIs. Data Conclusion Metabolic HP 13 C‐MRI in the prostate using ME‐bSSFP allows for differentiation between aggressive PCa and healthy tissue. Evidence Level 2 Technical Efficacy Stage 1
An accurate planar visualization (curved planar reformation - CPR) of intracranial arteries is mandatory for an improved luminal and mural assessment especially in low resolution Magnetic Resonance Imaging (MRI) data sets acquired in standard clinical settings. CPR visualization methods based on the centerline of the desired structure are fast and easy to implement but the accuracy strongly depends on the spatial resolution of the 3D data set and the size of the desired vessel. In the manuscript, a novel algorithm for fast and robust centerline calculation in multi-contrast 3D MRI data is presented. It considers the extracted surface of the vessel structure for a more accurate centerline prediction resulting in an enhanced CPR visualization of small vessels.
Background/Aims: Exposure toward positive emotional cues with – and without – reproductive significance plays a crucial role in daily life and regarding well-being as well as mental health. While possible adverse effects of oral contraceptive (OC) use on female mental and sexual health are widely discussed, neural processing of positive emotional stimuli has not been systematically investigated in association with OC use. Considering reported effects on mood, well-being and sexual function, and proposed associations with depression, it was hypothesized that OC users showed reduced neural reactivity toward positive and erotic emotional stimuli during early as well as later stages of emotional processing and also rated these stimuli as less pleasant and less arousing compared to naturally cycling (NC) women. Method: Sixty-two female subjects (29 NC and 33 OC) were assessed at three time points across the natural menstrual cycle and corresponding time points of the OC regimen. Early (early posterior negativity, EPN) and late (late positive potential, LPP) event-related potentials in reaction to positive, erotic and neutral stimuli were collected during an Emotional Picture Stroop Paradigm (EPSP). At each appointment, subjects provided saliva samples for analysis of gonadal steroid concentration. Valence and arousal ratings were collected at the last appointment. Results: Oral contraceptive users had significantly lower endogenous estradiol and progesterone concentrations compared to NC women. No significant group differences in either subjective stimulus evaluations or neural reactivity toward positive and erotic emotional stimuli were observed. For the OC group, LPP amplitudes in reaction to erotic vs. neutral pictures differed significantly between measurement times across the OC regimen. Discussion: In this study, no evidence regarding alterations of neural reactivity toward positive and erotic stimuli in OC users compared to NC was found. Possible confounding factors and lines for future research are elaborated and discussed.
An interaction between dopamine and oxytocin has been shown in several human and animal studies. Effects of oxytocin on dopaminergic activity depend on the location of dopaminergic neurons resulting in increased prosocial or decreased exploratory behavior. Both components are associated with attachment and the knowledge so far justifies investigating the interaction on a molecular genetic level with respect to adult attachment. A total number of N = 545 participants were genotyped for COMT rs4680 and OXTR rs53576. The Attachment-Style-Questionnaire (ASQ) was used to measure adult attachment. The interaction of COMT and OXTR yielded a significant result for the ASQ. The combination of the COMT-Met/Met and OXTR-AA genotype yielded significantly higher Need for Approval and Relationships as Secondary. The results confirm the interaction between dopamine and oxytocin for certain aspects of adult attachment as a "behavioral phenotype" and will be discussed with respect to a better understanding of the neurobiological underpinnings of attachment.
Hyperpolarized contrast agents (HyCAs) have enabled unprecedented magnetic resonance imaging (MRI) of metabolism and pH in vivo. Producing HyCAs with currently available methods, however, is typically time and cost intensive. Here, we show virtually-continuous production of HyCAs using parahydrogen-induced polarization (PHIP), without stand-alone polarizer, but using a system integrated in an MRI instead. Polarization of ≈2% for [1- 13 C]succinate-d 2 or ≈19% for hydroxyethyl-[1- 13 C]propionate-d 3 was created every 15 s, for which fast, effective, and well-synchronized cycling of chemicals and reactions in conjunction with efficient spin-order transfer was key. We addressed these challenges using a dedicated, high-pressure, high-temperature reactor with integrated water-based heating and a setup operated via the MRI pulse program. As PHIP of several biologically relevant HyCAs has recently been described, this Rapid-PHIP technique promises fast preclinical studies, repeated administration or continuous infusion within a single lifetime of the agent, as well as a prolonged window for observation with signal averaging and dynamic monitoring of metabolic alterations.
PURPOSE:To develop, optimize, and implement a single shot spiral turbo spin echo (TSE) sequence at 3T and to demonstrate its feasibility to acquire artifact free images of the central nervous system with 1 mm spatial resolution in <200 ms.THEORY AND METHODS:Spiral TSE sequences with annulated spiral segmentation have been implemented with different acquisition modes. In fixed mode, the duration of each spiral segment is fixed to fill the available acquisition time tacq . In tangential mode, the beginning of each spiral segment is reached via a straight tangential trajectory. Tangential mode allows faster transition and thus longer tacq for a given echo spacing (ESP), but less data points can be acquired per acquisition interval. Alternating between spiral-in and spiral-out readout in alternating echoes leads to a somewhat different point spread function for off-resonant spins.RESULTS:Images of the brain with 1 mm spatial resolution acquired with a variable density spiral with ∼40% undersampling can be acquired in a single shot. All acquisition modes produce comparable image quality. Only mild artifacts in regions of strong susceptibility effects can be observed for ESP of 10 ms and below. The use of variable flip angle schemes allows seamless acquisition of consecutive slices and/or dynamic scans without waiting time between consecutive acquisitions. Comparison with images acquired at 1.5T shows reduced susceptibility artifacts within the brain and facial structures.CONCLUSION:Single shot spiral TSE has been demonstrated to enable highly efficient acquisition of high-resolution images of the brain in <200 ms per slice.