Is driving a car a risk for Legionnaires' disease?

EPIDEMIOLOGY AND INFECTION(2009)

引用 26|浏览37
暂无评分
摘要
Legionnaires' disease (LD) is a major cause of severe community-acquired pneumonia but the Source and mode of transmission are not always apparent, especially in sporadic cases. We hypothesized that LD can be acquired from the air-conditioning systems of motor cars. Swabs were taken from the evaporator compartments of the air-conditioning system of scrapped cars. Healthy Subjects who were mainly employees of regional transportation companies were tested for antibody to Legionella pneumophila serogroups 1-6; they also completed a questionnaire. Legionella species were detected in 11/22 scrapped cars by the loop-mediated isothermal amplification method. The prevalence of microplate agglutination titres >= 1 :32 was significantly higher in subjects who sometimes used car air-conditioning systems. Although we did not prove a direct link between Legionella spp. in the car evaporator and LD, Our findings point to a potential risk of car air-conditioning systems in LD, which needs further investigation.
更多
查看译文
关键词
Air conditioning,cars,Legionnaires' disease