Probing the Electrode-Neuron Interface With Focused Cochlear Implant Stimulation

Julie Arenberg Bierer, Arenberg Bierer,John C. Middlebrooks,A. J. Spahr,L. M. Litvak,M. F. Dorman,A. R. Bohanan, L. N. Mishra, Identification With, A. Kral,J. Tillein,P. Hubka,D. Schiemann, S. Heid,R. Hartmann,A. K. Engel,H. H. Lim,M. Lenarz, T. Lenarz, J. Arenberg Bierer

TRENDS IN AMPLIFICATION(2010)

引用 99|浏览9
暂无评分
摘要
Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode-neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode-neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception.
更多
查看译文
关键词
cochlear implant,electrode configuration,neural survival,spectral resolution,psychophysics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要