Detecting myocardial ischaemia using miniature ultrasonic transducers--a feasibility study in a porcine model.

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY(2010)

引用 18|浏览14
暂无评分
摘要
Background: Detection of myocardial ischaemia during and after cardiac surgery remains a challenge. Echocardiography is more sensitive in ischaemia detection than echocardiography (ECG) and haemodynamic monitoring, but demands repeated examinations for monitoring over time. We have developed and validated an ultrasonic system that permits continuous real-time assessment of myocardial ischaemia using miniature epicardial ultrasound transducers. Methods: In an open-chest porcine model (n = 8), prototype ultrasound transducers were fixed on the epicardium in the left anterior descending and circumflex coronary artery supply regions, providing continuous measurement of transmural myocardial velocities. Peak systolic velocity and post-systolic velocity were recorded simultaneously with ECG, left ventricular pressure and arterial pressure. Two-dimensional (2D) echocardiographic strain was used as a reference. Global changes were induced by infusing fluid, epinephrine, nitroprusside and esmolol. Regional changes were induced by occluding the left anterior descending coronary artery (LAD). Subsequent LAD stenosis was performed in a subgroup, with flow reduction to 50% of baseline level and further to occlusion. Results: Systolic velocity in the LAD region decreased during LAD occlusion (0.9 +/- 0.1 to 0.1 +/- 0.1 cm s(-1), P < 0.01), whereas post-systolic velocity increased (0.3 +/- 0.1 to 2.3 +/- 0.1 cm s(-1), P < 0.01). No changes occurred in the circumflex coronary artery (CX) region. Severe ischaemia was confirmed by reduction in 2D echocardiography strain calculations. Changes in myocardial velocities assessed by miniature transducer during ischaemia differed from changes during all global interventions. Significant reduction in systolic velocity occurred at 50% LAD flow (0.9 +/- 0.1 to 0.5 +/- 0.1 cm s(-1), P = 0.02) with further decrease on following occlusion (0.0 +/- 0.0 cm s(-1), P < 0.01). Post-systolic velocity increased both from baseline to 50% LAD flow, and further to occlusion. Conclusion: The epicardial transducers provided continuous assessment of regional myocardial function and detected ischaemia with high sensitivity and specificity. Further development of this system may provide a useful tool for myocardial monitoring during and after cardiac surgery. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
更多
查看译文
关键词
Myocardial ischaemia,Cardiac surgical procedures,Echocardiography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要