Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: An in vitro study

The Journal of Prosthetic Dentistry(2009)

引用 46|浏览3
暂无评分
摘要
Statement of problem. Nonparallel implants, when used to retain overdentures, may present a restorative challenge, particularly when using attachments. Premature wear of the components and loss of retention may be observed, resulting in increased maintenance. Purpose. The purpose of this study was to compare the retentive behavior, over time, of spherical attachments when used in nonparallel and parallel Implant scenarios In a cyclic testing mode. Material and methods. Thirty sets of 2-implant-supported overdenture models were evaluated: 4.0 x 13-mm implants (Astra-Tech Osseospeed) with 1.5-mm ball abutments (Astra-Tech) were used as the intraoral analog to the implants, and spherical attachments (Preci Clix) were used as the overdenture analog. Five different attachment and implant-abutment complex angulations were evaluated. Angulation was determined by deviation from the vertical reference plane. The groups consisted of the following: Group 0-0, 0-degree implants/0-degree attachments; Group 10-0, 10-degree implants/0-degree attachments; Group 15-0, 15-degree implants/0-degree attachments; Group 10-10, 10-degree implants/10-degree attachments; and Group 15-15, 15-degree implants/15-degree attachments. The specimens were subjected to cyclic loading (3500 cycles). Peak and valley retention loads were recorded at the first pull and then after every 100 cycles; therefore, 36 data points per specimen were recorded. Nonparametric analyses followed by post hoc analyses were conducted to test for differences in median peak load among groups (alpha=.05). Results. Peak lead to dislodgment values for all groups ranged from 11.42, N to 23.56 N. Group 0-0 had the highest median retention value overall, 21.3 N, and Group 15-15 had the lowest median value, 17.3 N. Nonparametric analyses showed significant differences between Groups 0-0 and 15-15 (P=.014.); and 10-0 and 15-15 (P=.002). Conclusions. Within the limitations of this study, it was observed that there was a decrease in retention in the groups with 30-degree divergent implants and divergent attachments compared to the groups with parallel implants and parallel attachments. in general, retention varied from 11 N to 23 N, and attachment retention stabilized after initial loss in most groups. (J Prosthet Dent 2009;101:231-238)
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要