Determination of iron and copper in old manuscripts by slurry sampling graphite furnace atomic absorption spectrometry and laser ablation inductively coupled plasma mass spectrometry1This paper was published in the special issue of the Third European Furnace Symposium, Prague, Czech Republic, June 1998.1

SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY(1999)

引用 38|浏览6
暂无评分
摘要
The analytical strategy for the evaluation of iron and copper distribution in ancient manuscript by slurry sampling graphite furnace atomic absorption spectrometry (GFAAS) and laser ablation inductively coupled plasma mass spectrometry (LA ICP-MS) is presented. The aim of the study was the investigation of ink corrosion in the written area of the ancient manuscript. GFAAS was used to determine the amount of both metals in micro-samples of paper. Determination is based on aqueous standards and the precision using slurry sampling varies in the range from 0.8 to 10.0% R.S.D. for iron and from 0.3 to 7.6% R.S.D. for copper. The content of iron and copper varies significantly between written (32.8 +/- 0.9 mg g(-1) of iron, 15.2 +/- 0.5 mg g(-1) of copper) and non-written (3.3 +/- 1.3 mg g(-1) of iron, 1.6 +/- 0.8 mg g(-1) of copper) areas of the investigated manuscript. LA ICP-MS was used to define the distribution patterns of iron and copper on the surface of the manuscript. (C) 1999 Elsevier Science B.V. All rights reserved.
更多
查看译文
关键词
ink,Fe,Cu,slurry sampling,electrothermal atomic absorption spectrometry,(ETAAS),laser ablation,inductively coupled plasma (ICP)