Experimental studies on cold-formed steel angle tension members

GEMESED'11 Proceedings of the 4th WSEAS international conference on Energy and development - environment - biomedicine(2011)

引用 24|浏览3
暂无评分
摘要
Cold formed steel angles with bolted connections connected on single leg normally undergo net section failure for relatively longer connections. Since only one leg is connected, the stresses lag in the elements, which are not connected directly (referred as shear lag effect) reducing the tensile capacity of angles. Twelve experiments have been carried out on single angle bolted tension members connected by single leg to investigate the mode of failure and the ultimate load carrying capacity. The parameters considered in this experimental programme are: number of bolts/connection length, shear lag distance and ratio of connected leg length to unconnected leg length. All the specimens underwent net section rupture of failure.
更多
查看译文
关键词
cold-formed steel angle tension,connection length,shear lag distance,experimental study,section rupture,shear lag effect,connected leg length,section failure,unconnected leg length,single leg,tensile capacity,single angle,stress concentration
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper