R&D and maintenance on graphite tile of divertor region at EAST

Fusion Engineering and Design(2012)

引用 1|浏览18
暂无评分
摘要
EAST, with full superconducting magnetic coils, had been designed and constructed to address the scientific and engineering issues under steady state operation. The in-vessel components are full graphite tiles as first wall had been operated successfully. In the experiment campaign of 2010, the H mode operation and 1 MA operation have been gotten on EAST. However, in some case, some of the graphite tiles of divertor region are damaged with the plasma parameter enhanced. As most of the damaged graphite tiles are in the divertor region, they are probably damaged by the electro-magnetic force of the halo current when the VDEs occur. The force of the halo current is re-estimated. The structure analysis has been done by the ANSYS software. From the analysis result. It can be obtained that the stress is larger than the allowable stress when the halo current on the graphite tile is larger than 2.7 kA. The tensile testing of the graphite also has been done. As the result, the graphite tiles are damaged when the forces are up to 2400 N. To deal with the problem, two proposes are accepted. In the one hand, the new type graphite material is used, whose tensile strength is up to 45 MPa. In the other hand, the structure of the graphite tiles is optimized. © 2012 Elsevier B.V.
更多
查看译文
关键词
R&D,Graphite tile,Divertor,EAST
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要