A novel method to position an endotracheal tube at the correct depth using an infrared sensor stylet

CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE(2013)

引用 8|浏览4
暂无评分
摘要
Purpose This study is a feasibility assessment to determine the ability of novice users to utilize an infrared (IR) sensor stylet as a guide to position the tip of the endotracheal tube (ETT) 40 mm proximal to the carina in the swine trachea. Methods We developed a stylet system using an IR sensor attached to the tip of a stylet to facilitate measuring the distance of the ETT from the carina. The indicator lamp of the IR sensor system turns on through calibration when the ETT tip arrives at a point 20 mm proximal to the carina. In order to place the ETT tip 40 mm (middle of 20-60 mm) from the carina after the indicator lamp turns on, the operator uses the ETT marker to withdraw the ETT 20 mm. For this study, five fresh swine airways were used in random order after drawing lots, and ten novices were recruited to attempt the procedure ten times on each swine’s airway. Results Five hundred endotracheal intubations were performed. For the target distance of 40 mm from the ETT tip to the carina, the mean (standard deviation) of the total data set was 37.9 (3.5) mm; all data were within a 20-60 mm range (500/500), and 98.2% (491/500) of the attempts fell within the 30-50 mm range. Conclusions The IR sensor stylet system can facilitate correct positioning of the ETT tip at an appropriate depth above the carina in the swine trachea. Evaluation of the IR sensor stylet methodology in human subjects is warranted.
更多
查看译文
关键词
Chest Radiography,Ultrasonic Sensor,Fibreoptic Bronchoscopy,Correct Depth,Human Esophagus
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要