Occupational noise exposure assessment in intensive swine farrowing systems: dosimetry, octave band, and specific task analysis.

Michael J Humann, Kelly J Donham, Martin L Jones,Chandran Achutan,Brian J Smith

Journal of agromedicine(2005)

引用 18|浏览3
暂无评分
摘要
The scientific literature is lacking in published agricultural noise assessments for employees of swine confinement facilities that have included dosimeter data, octave band analysis, or specific task exposure assessments. This study reports on the former three types of noise assessments in the farrowing stage of swine. Dosimeter data on workers revealed all assessments to be greater than 90 decibels measured on the A-scale (dBA), which exceeds the 85 dBA National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL). RELs were exceeded for all of the employees monitored in the swine facility, as well as the part-time employees who power-washed the farrowing rooms. The recorded time-weighted values were actually underestimated slightly because the dosimeters were set to record only noise at 85 dBA and higher.
更多
查看译文
关键词
agriculture,exposure assessment,noise,noise reduction