Validity and concordance of electronic health records in primary care (AP-Madrid) for surveillance of diabetes mellitus. PREDIMERC study]

Gaceta Sanitaria(2014)

引用 23|浏览0
暂无评分
摘要
To assess the validity and concordance of diabetes data in the electronic health records of primary care (Madrid-PC) by comparing with those from the PREDIMERC study.The sensitivity, specificity, positive predictive value, negative predictive value and kappa index of diabetes cases recorded in the health records of Madrid-PC were calculated by using data from PREDIMERC as the gold standard. The prevalence of diabetes was also determined according to each data source.The sensitivity of diabetes recorded in Madrid-PC was 74%, the specificity was 98.8%, the positive predictive value was 87.9%, the negative predictive value was 97.3%, and the kappa index was 0.78. The prevalence of diabetes recorded in Madrid-PC was 6.7% versus 8.1% by PREDIMERC, where known diabetes was 6.3%.The electronic health records of primary care are a valid source for epidemiological surveillance of diabetes in Madrid.
更多
查看译文
关键词
Diabetes mellitus,Epidemiología,Vigilancia epidemiológica,Sensibilidad y especificidad,Historia clínica electrónica