Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study

Critical care (London, England)(2014)

引用 82|浏览9
暂无评分
摘要
Introduction Functional assessment of arterial load by dynamic arterial elastance (Ea dyn ), defined as the ratio between pulse pressure variation (PPV) and stroke volume variation (SVV), has recently been shown to predict the arterial pressure response to volume expansion (VE) in hypotensive, preload-dependent patients. However, because both SVV and PPV were obtained from pulse pressure analysis, a mathematical coupling factor could not be excluded. We therefore designed this study to confirm whether Ea dyn , obtained from two independent signals, allows the prediction of arterial pressure response to VE in fluid-responsive patients. Methods We analyzed the response of arterial pressure to an intravenous infusion of 500 ml of normal saline in 53 mechanically ventilated patients with acute circulatory failure and preserved preload dependence. Ea dyn was calculated as the simultaneous ratio between PPV (obtained from an arterial line) and SVV (obtained by esophageal Doppler imaging). A total of 80 fluid challenges were performed (median, 1.5 per patient; interquartile range, 1 to 2). Patients were classified according to the increase in mean arterial pressure (MAP) after fluid administration in pressure responders (≥10%) and non-responders. Results Thirty-three fluid challenges (41.2%) significantly increased MAP. At baseline, Ea dyn was higher in pressure responders (1.04 ± 0.28 versus 0.60 ± 0.14; P <0.0001). Preinfusion Ea dyn was related to changes in MAP after fluid administration ( R 2 = 0.60; P <0.0001). At baseline, Ea dyn predicted the arterial pressure increase to volume expansion (area under the receiver operating characteristic curve, 0.94; 95% confidence interval (CI): 0.86 to 0.98; P <0.0001). A preinfusion Ea dyn value ≥0.73 (gray zone: 0.72 to 0.88) discriminated pressure responder patients with a sensitivity of 90.9% (95% CI: 75.6 to 98.1%) and a specificity of 91.5% (95% CI: 79.6 to 97.6%). Conclusions Functional assessment of arterial load by Ea dyn , obtained from two independent signals, enabled the prediction of arterial pressure response to fluid administration in mechanically ventilated, preload-dependent patients with acute circulatory failure.
更多
查看译文
关键词
bioinformatics,biomedical research
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要