Chrome Extension
WeChat Mini Program
Use on ChatGLM

Optimal Spectral Regions for Laser Excited Fluorescence Diagnostics for Point of Care Application

AIP conference proceedings(2011)

Cited 2|Views5
No score
Abstract
The tissue fluorescence gives the response of light emitting molecule signature, and characterizes the cell composition and peculiarities of metabolism. Both are useful for the biomedical diagnostics, as reported in previous our and others works. The present work demonstrates the results of application of laser excited autofluorescence for diagnostics of pathology in genital tissues, and the feasibility for the bedside at "point of care - off lab" application. A portable device using the USB spectrophotometer, micro laser (355 nm Nd:YAG, 0,5 ns pulse, repetition rate 10 kHz, output power 15 mW), three channel optical fiber and computer with diagnostic program was designed and ready for clinical trial to be used for cytology and biopsy specimen on site diagnostics, and for the endoscopy/puncture procedures. The biopsy and cytology samples, as well as intervertebral disc specimen were evaluated by pathology experts and the fluorescence spectra were investigated in the fresh and preserved specimens. The spectra were recorded in the spectral range 350-900 nm. At the initial stage the Gaussian components of spectra were found and the Mann-Whitney test was used for the groups' differentiation and the spectral regions for optimal diagnostics purpose were found. Then a formal dividing of spectra in the components or the definite width bands, where the main difference of the different group spectra was observed, was used to compare these groups. The ROC analysis based diagnostic algorithms were created for medical prognosis. The positive prognostic values and negative prediction values were determined for cervical Liquid PAP smear supernatant sediment diagnosis of being Cervicitis and Norma versus CIN2+. In a case of intervertebral disc the analysis allows to get the additional information about the disc degeneration status. All these results demonstrated an efficiency of the proposed procedure and the designed device could be tested at the point-of-care site or for intervertebral disc operations.
More
Translated text
Key words
Photomedicine,fluorescence spectroscopy,Real-time diagnosis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined