The Q(Weak) Experimental Apparatus

T. Allison,M. Anderson,D. Androic,D. S. Armstrong,A. Asaturyan,T. Averett, R. Averill,J. Balewski, J. Beaufait,R. S. Beminiwattha,J. Benesch,F. Benmokhtar, J. Bessuille,J. Birchall, E. Bonnelli,J. D. Bowman, P. Brindza, D. B. Brown, R. D. Carlini, G. D. Cates, B. Cavness, G. Clark,J. C. Cornejo,S. Covrig Dusa,M. M. Dalton,C. A. Davis, D. C. Dean,W. Deconinck, J. Diefenbach,K. Dow, J. F. Dowd,J. A. Dunne,D. Dutta, W. S. Duvall,J. R. Echols,M. Elaasar, W. R. Falk,K. D. Finelli,J. M. Finn,D. Gaskell,M. T. W. Gericke,J. Grames,V. M. Gray,K. Grimm, F. Guo,J. Hansknecht,D. J. Harrison, E. Henderson, J. R. Hoskins, E. Ihloff, K. Johnston,D. Jones,M. Jones,R. Jones,M. Kargiantoulakis, J. Kelsey,N. Khan,P. M. King,E. Korkmaz,S. Kowalski, A. Kubera, J. Leacock,J. P. Leckey,A. R. Lee,J. H. Lee,L. Lee, Y. Liang,S. Macewan, D. Mack,J. A. Magee, R. Mahurin,J. Mammei,J. W. Martin,A. Mccreary,M. H. Mcdonald,M. J. Mchugh,P. Medeiros,D. Meekins,J. Mei,R. Michaels, A. Micherdzinska,A. Mkrtchyan,H. Mkrtchyan, N. Morgan,J. Musson,K. E. Mesick,A. Narayan,L. Z. Ndukum,V. Nelyubin,Nuruzzaman,W. T. H. Van Oers, A. K. Opper,S. A. Page,J. Pan,K. D. Paschke,S. K. Phillips,M. L. Pitt,M. Poelker,J. F. Rajotte,W. D. Ramsay, W. R. Roberts,J. Roche, P. W. Rose, B. Sawatzky,T. Seva,M. H. Shabestari,R. Silwal, N. Simicevic,G. R. Smith, S. Sobczynski,P. Solvignon, D. T. Spayde, B. Stokes,D. W. Storey,A. Subedi, R. Subedi,R. Suleiman, V. Tadevosyan,W. A. Tobias, V. Tvaskis,E. Urban,B. Waidyawansa, P. Wang,S. P. Wells,S. A. Wood,S. Yang,S. Zhamkochyan, R. B. Zielinski

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT(2015)

引用 39|浏览21
暂无评分
摘要
The Jefferson Lab experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise (e) over right arrowp asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 mu A of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Muller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q(2)=0.025 GeV2 was determined using dedicated low-current (similar to 100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet. (C) 2015 Elsevier B.V All rights reserved.
更多
查看译文
关键词
Parity violation, Electron scattering, High luminosity, Liquid hydrogen target, Particle detectors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要