Analysis of testbeam data of the highly granular RPC-steel CALICE digital hadron calorimeter and validation of GEANT4 Monte Carlo models

M. Chefdeville,J. Repond, J. Schlereth, J. R. Smith, D. Trojand, L. Xia, Q. Zhang,J. Apostolakis,C. Grefe, V Ivantchenko, G. Folger, A. Ribon, V Uzhinskiy,G. C. Blazey, A. Dyshkant, K. Francis, V Zutshi, O. Bach, V Bocharnikov, E. Brianne, K. Gadow, P. Goettlicher,O. Hartbrich, D. Heuchel, F. Krivan, K. Krueger,J. Kvasnicka, S. Lu,C. Neubuser, O. Pinto, A. Provenza, M. Reinecke, F. Sefkow, S. Schuwalow, Y. Sudo,H. L. Tran, P. Buhmann,E. Garutti,D. Lomidze, S. Martens, M. Matysek, B. Bilki, D. Northacker, Y. Onel,B. van Doren,G. W. Wilson, K. Kawagoe, Y. Miura,R. Mori,I Sekiya, T. Suehara,T. Yoshioka,D. Belver,E. Calvo Alamillo, M. C. Fouz,H. Garcia Cabrera,J. Marin,J. Navarrete,J. Puerta Pelayo, A. Verdugo, F. Corriveau, B. Freund, M. Chadeeva, M. Danilov,M. Gabriel, L. Emberger,C. Graf, Y. Israeli,F. Simon,M. Szalay, H. Windel, S. Bilokin, J. Bonis, A. Irles, R. Poschl, A. Thiebault, F. Richard,D. Zerwas, J. Cvach, M. Janata, M. Kovalcuk, I Polak, J. Smolik, V. Vrba,J. Zalesak, J. Zuklin, T. Takeshita, A. Elkhalii, M. Goetze, C. Zeitnitz,S. Chang,A. Khan,D. H. Kim, D. J. Kong,Y. D. Oh

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT(2019)

引用 6|浏览10
暂无评分
摘要
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of 1 x 1 cm(2) and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on GEANT4, which utilise different electromagnetic and hadronic physics lists.
更多
查看译文
关键词
Imaging calorimeters, Digital calorimetry, Resistive plate chambers, GEANT4 models, Gas detectors, Linear collider detectors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要