The Effectiveness of Blood Metal Ions in Identifying Bilateral Metal-on-metal Total Hip Arthroplasty Patients at Risk of Adverse Reactions to Metal Debris

Acta orthopaedica belgica(2018)

引用 23|浏览14
暂无评分
摘要
We investigated whether blood metal ions could effectively identify bilateral metal-on-metal total hip arthroplasty (THA) patients at risk of adverse reactions to metal debris (ARMD). Whole blood metal ions were sampled in 50 patients with bilateral 36mm Corail-Pinnacle THAs. Patients were divided into ARMD (n=10) and non-ARMD groups (n=40), with optimal ion thresholds for identifying ARMD determined using receiver operating characteristic analysis. Maximum cobalt or chromium produced the highest area under the curve (71.8%). The optimal ion threshold for distinguishing between patients with and without ARMD was 4.0 mu g/l (90.0.%=sensitivity, 65.0%=specificity, 39.1%=positive predictive value, 96.3%=negative predictive value). Fixed regulatory authority thresholds missed more patients with ARMD (10%-12% missed) compared to our threshold (2% missed). Bilateral THA patients with blood metal ions below our threshold were at low-risk of ARMD. Compared to currently recommended fixed authority thresholds, our threshold appears preferable for managing patients with these particular implants.
更多
查看译文
关键词
adverse reactions to metal debris,blood metal ions,metal-on-metal,revision,total hip arthroplasty