Commissioning Results Of The World'S First Diode-Pumped 10hz Pw Laser

T. Spinka,E. Sistrunk,A. Bayramian, J. P. Armstrong,S. Baxamusa,S. Betts, D. R. Bopp,S. Buck, K. Charron, J. Cupal, R. Demaret,R. Deri,J. M. Di Nicola,Alvin C. Erlandson, E. S. Fulkerson, C. Gates, J. Horner,J. Horacek,J. Jarboe, K. Kasl,D. Kim,E. Koh, L. Koubikova, R. Lanning, J. Lusk, W. Maranville,Christopher D. Marshall,D. Mason,Joseph A. Menapace,Philip E. Miller, P. Mazurek,A. J. Naylon, James D. Nissen,J. Novak, D. Peceli, P. Rosso,Kathleen I. Schaffers, T. Silva,D. Smith,J. Stanley, R. Steele,Christopher J. Stolz,Tayyab I. Suratwala,S. Telford,J. Thoma, D. VanBlarcom,J. Weiss,Paul J. Wegner,B. Rus,C. Haefner

2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC)(2017)

引用 0|浏览10
暂无评分
摘要
We have demonstrated the worldu0027s highest average power, fully diode-pumped, petawatt-class peak power laser, the High-repetition-rate Advanced Petawatt Laser System (HAPLS) [1-3]. These first commissioning results at 16J (stretched) at 3%Hz fully validate projected performance of 30J/30fs (u003e1PW) at 10Hz. The laser has been operated at this intermediate level at Lawrence Livermore National Laboratory to demonstrate integrated performance of all subsystems and provide benchmarking data to laser performance models before further increasing energy and peak power. Data was obtained during multiple campaigns, exceeding several hours of run time, and a snapshot of 60min of data is shown in Fig. 1. The average pump laser 1ω (1053nm) energy was 97J with an rms stability of 0.7%, 2ω (527nm) energy at the Ti:sapphire power amplifier was 62J, and the average stretched short pulse energy was 16J. A full-aperture diagnostic suite allows simultaneous, single-shot measurement of energy, spectrum, beam quality, and pulse duration at full repetition rate. Single-shot SPIDER retrieved pulse shapes (Fig. 1 inset) with an average pulse duration over 12000 consecutive shots of 28.6fs (rms=1.4fs). The mean pulse duration is consistent with the measured spectral bandwidth and is ∼1.2× the transform limit. All results shown are raw data without filtering or averaging, demonstrating the exceptional pulse characteristics, repeatability, and stability of the entire laser system.
更多
查看译文
关键词
laser system stability,repeatability,pulse characteristics,transform limit,spectral bandwidth,mean pulse duration,average pulse duration,pulse shapes,single-shot SPIDER,full repetition rate,beam quality,single-shot measurement,full-aperture diagnostic suite,average stretched short pulse energy,Ti:sapphire power amplifier,rms stability,average pump laser,laser performance models,Lawrence Livermore National Laboratory,intermediate level,HAPLS,High-repetition-rate Advanced Petawatt Laser System,fully diode-pumped petawatt-class peak power laser,diode-pumped PW laser,energy 16 J,energy 30 J,energy 97 J,frequency 10 Hz,energy 62 J,time 28.6 fs,time 60 min,wavelength 1053 nm,wavelength 527 nm,Al2O3:Ti
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要