Improving the results of transarterial embolization of type 2 endoleaks with the embolic polymer Onyx.

VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES(2016)

引用 10|浏览4
暂无评分
摘要
Introduction: Type 2 endoleaks (T2E) occur in 10 to 20% of patients after endovascular abdominal aortic aneurysm repair (EVAR) and remain a significant clinical issue. Aim: To evaluate the efficacy and clinical outcomes of transarterial treatment of persistent type II endoleaks after EVAR using the liquid embolic Onyx. Material and methods: From February 2012 to August 2015 transarterial T2E embolization was attempted in 22 patients (21 men, median age: 73, range: 62-88 years). Indications for treatment included an increase in the diameter of the aneurysm sac above 5 mm and a persistent endoleak observed for more than 6 months. Mean time from EVAR to endoleak treatment was 43 months (range: 2-125 months). Results: Primary technical success was achieved in 17 (77.3%) patients and secondary technical success in 81.8%, with 0% in-hospital mortality The mean procedure time was 95 +/- 48 min, with an average fluoroscopy time of 54 25 min. The mean amount of Onyx used was 7.5 +/- 6.6 ml. Clinical success was seen in 17/21 patients with follow-up imaging (80.9%). Mean follow-up time was 17 months (range: 3-38 months). Conclusions: Onyx has been shown to effectively stabilize previous aneurysm growth as a result of the T2E in the majority of our patients. Transarterial embolization of T2E can be significantly improved as compared to previously reported results by using liquid embolic polymers such as Onyx.
更多
查看译文
关键词
endoleak,aortic aneurysm,therapeutic embolization,Onyx copolymer
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要