谷歌浏览器插件
订阅小程序
在清言上使用

A 1-Year Comparison of TCu380Ag Versus TCu380A Intrauterine Contraceptive Devices in India.

International journal of gynaecology and obstetrics(2019)

引用 4|浏览22
暂无评分
摘要
Objective: To compare TCu380Ag and TCu380A intrauterine contraceptive devices after 1 year of use. Methods: A prospective randomized controlled trial was conducted among healthy married women aged 20-35 years who attended the family planning clinics of three tertiary centers in India between August 1, 2015, to March 31, 2018. The TCu380Ag group (n=300) received one of three sizes of this device depending on uterocervical length: maxi (8.0-9.0 cm), normal (7.0-8.5 cm), or mini (6.0-7.5 cm). The remaining 300 participants received TCu380A. Follow--up was conducted at 3--monthly intervals to assess continuation rate, acceptability, efficacy, adverse effects, and complications. Results: The TCu380Ag group had a higher continuation rate than the TCu380A group at 1 year (84.0% vs 75.8%; P=0.01), with an efficacy of 99.6% versus 100.0% (P>0.05). Overall estimated continuation rates were 94.5% (95% confidence interval [CI] 91.7%96.4%) and 88.4% (95% CI 83.2%-91.5%), respectively (P=0.026). Use of TCu380Ag was associated with fewer adverse effects (heavy menstrual bleeding, abdominal pain, or expulsion) when compared with TCu380A (P>0.05 for all comparisons). Discontinuation rates owing to adverse effects were 6.59% for TCu380Ag versus 13.26% for TCu380A (P=0.01). Conclusions: Varying sizes of TCu380Ag could provide an alternative to TCu380A.
更多
查看译文
关键词
Acceptability,Continuation rate,Efficacy,Intrauterine contraceptive device,TCu380A,TCu380Ag