摘要
The P300 Brain-Computer Interface (BCI) is a well-established communication channel for severely disabled people. The P300 event-related potential is mostly characterized by its amplitude or its area, which correlate with the spelling accuracy of the P300 speller. Here, we introduce a novel approach for estimating the efficiency of this BC by considering the P300 signal-to-noise ratio (SNR), a parameter that estimates the spatial and temporal noise levels and has a significantly stronger correlation with spelling accuracy. Furthermore, we suggest a Gaussian noise model, which utilizes the P300 event-related potential SNR to predict spelling accuracy under various conditions for LDA-based classification. We demonstrate the utility of this analysis using real data and discuss its potential applications, such as speeding up the process of electrode selection.
更多
查看译文
关键词
P300 speller,signal-to-noise ratio,LDA,electroencephalography,symbol selection accuracy