Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

Collaboration EXO-, :,Anton G.,Badhrees I.,Barbeau P. S., Beck D.,Belov V.,Bhatta T.,Breidenbach M.,Brunner T., Cao G. F., Cen W. R., Chambers C., Cleveland B., Coon M., Craycraft A., Daniels T.,Darroch L., Daugherty S. J., Davis J.,Delaquis S.,Der Mesrobian-Kabakian A., DeVoe R.,Dilling J.,Dolgolenko A.,Dolinski M. J.,Echevers J.,Fairbank Jr. W., Fairbank D., Farine J.,Feyzbakhsh S., Fierlinger P., Fudenberg D.,Gautam P., Gornea R.,Gratta G.,Hall C.,Hansen E. V., Hoessl J., Hufschmidt P., Hughes M.,Iverson A.,Jamil A., Jessiman C.,Jewell M. J.,Johnson A., Karelin A.,Kaufman L. J.,Koffas T., Krucken R., Kuchenkov A., Kumar K. S., Lan Y., Larson A., Lenardo B. G.,Leonard D. S.,Li G. S.,Li S.,Li Z., Licciardi C.,Lin Y. H.,MacLellan R., McElroy T.,Michel T.,Mong B.,Moore D. C., Murray K.,Neilson R., Njoya O.,Nusair O., Odian A.,Ostrovskiy I.,Piepke A.,Pocar A.,Retiere F., Robinson A. L.,Rowson P. C., Runge J., Schmidt S.,Sinclair D.,Soma A. K., Stekhanov V.,Tarka M., Todd J., Tolba T., Tosi D., Totev T. I., Veenstra B.,Veeraraghavan V., Vuilleumier J. -L., Wagenpfeil M.,Watkins J.,Weber M., Wen L. J., Wichoski U., Wrede G., Wu S. X.,Xia Q.,Yahne D. R.,Yang L., Yen Y. -R.,Zeldovich O. Ya., Ziegle T.

PHYSICAL REVIEW C(2020)

引用 23|浏览5
暂无评分
摘要
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by gamma interactions from Th-228 (2615 keV), Ra-226 (1764 keV), and Co-60 (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5 +/- 0.5 (syst.) +/- 0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta-decay detectors.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要