Effect of Substrate Permeability on Scanning Ion Conductance Microscopy: Uncertainty in Tip-Substrate Separation and Determination of Ionic Conductivity.

ANALYTICAL CHEMISTRY(2019)

引用 15|浏览13
暂无评分
摘要
Composite electrodes can significantly improve the performance of an electrochemical device by maximizing surface area and active loading. Typically, additives such as carbon are used to improve conductivity and a polymer is used as a binder, leading to a heterogeneous surface film with thickness on the order of 10 s of micrometers. For such composite electrodes, good ionic conduction within the film is critical to capitalize on the increased loading of active material and surface area. Ionic conductivity within a film can be tricky to measure directly, and homogenization models based on porosity are often used as a proxy. SICM has traditionally been a topography-mapping microscopy method for which we here outline a new function and demonstrate its capacity for measuring ion conductivity within a lithium-ion battery film.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper