谷歌浏览器插件
订阅小程序
在清言上使用

A Novel Method of Calculating Stroke Volume Using Point-of-care Echocardiography

Cardiovascular ultrasound(2020)

引用 3|浏览6
暂无评分
摘要
Abstract Background Point-of-care transthoracic echocardiography (POC-TTE) is essential in shock management, allowing for stroke volume (SV) and cardiac output (CO) estimation using left ventricular outflow tract diameter (LVOTD) and left ventricular velocity time integral (VTI). Since LVOTD is difficult to obtain and error-prone, the body surface area (BSA) or a modified BSA (mBSA) is sometimes used as a surrogate (LVOTDBSA, LVOTDmBSA). Currently, no models of LVOTD based on patient characteristics exist nor have BSA-based alternatives been validated. Methods Focused rapid echocardiographic evaluations (FREEs) performed in intensive care unit patients over a 3-year period were reviewed. The age, sex, height, and weight were recorded. Human expert measurement of LVOTD (LVOTDHEM) was performed. An epsilon-support vector regression was used to derive a computer model of the predicted LVOTD (LVOTDCM). Training, testing, and validation were completed. Pearson coefficient and Bland-Altman were used to assess correlation and agreement. Results Two hundred eighty-seven TTEs with ideal images of the LVOT were identified. LVOTDCM was the best method of SV measurement, with a correlation of 0.87. LVOTDmBSA and LVOTDBSA had correlations of 0.71 and 0.49 respectively. Root mean square error for LVOTDCM, LVOTDmBSA, and LVOTDBSA respectively were 13.3, 37.0, and 26.4. Bland-Altman for LVOTDCM demonstrated a bias of 5.2. LVOTDCM model was used in a separate validation set of 116 ideal images yielding a linear correlation of 0.83 between SVHEM and SVCM. Bland Altman analysis for SVCM had a bias of 2.3 with limits of agreement (LOAs) of − 24 and 29, a percent error (PE) of 34% and a root mean square error (RMSE) of 13.9. Conclusions A computer model may allow for SV and CO measurement when the LVOTD cannot be assessed. Further study is needed to assess the accuracy of the model in various patient populations and in comparison to the gold standard pulmonary artery catheter. The LVOTDCM is more accurate with less error compared to BSA-based methods, however there is still a percentage error of 33%. BSA should not be used as a surrogate measure of LVOTD. Once validated and improved this model may improve feasibility and allow hemodynamic monitoring via POC-TTE once it is validated.
更多
查看译文
关键词
Echocardiography,POCUS,Hemodynamic monitoring,Cardiac output,Fluid resuscitation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要