A Novel Digital And Visualized Guided Bone Regeneration Procedure And Digital Precise Bone Augmentation: A Case Series

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH(2021)

引用 23|浏览11
暂无评分
摘要
Background Although the traditional bone augmentation technology can basically meet the clinical needs at present, the effect of bone augmentation in most cases is related to the experience of the operator. Propose This study commits to providing a digital solution for precise bone augmentation in the field of oral implantology. Materials and methods After collecting the data of patients' intraoral scanning and DICOM (digital imaging and communications in medicine), the implant position is digitally designed, and the alveolar bone is digitally augmented around the ideal implant position. On the premise of ensuring that the thickness of labial bone is 2 mm, and there is sufficient alveolar bone 3 to 4 mm apically from the ideal gingival margin for implant placing, we carry out excessive augmentation of 0.5 and 1 mm on the labial bone and alveolar crest, respectively, to compensate for possible bone resorption after 6 months. After 3D printing the reconstructed alveolar bone model, the titanium mesh is trimmed and preformed on the alveolar bone model. Outcomes are reported in terms of mean values (5%-95% percentile values). Results Thirty implant sites have accepted this novel virtually designed alveolar bone augmentation. Before the second-stage surgery, the average vertical bone gain was 2.48 mm (0.29-6.32), the average horizontal bone gain was 4.11 mm (1.19-8.74), the average height of the residual alveolar bone above the implant platform was 1.44 mm (0.59-2.92), the average thickness of the labial bone width at the implant platform was 2.00 mm (0.93-3.64), the average thickness of the labial bone width at 2 mm apically from the implant platform was 2.74 mm (1.40-5.46). The virtual augmentation of each tooth position was 349.41 mm(3)(165.70-482.70), while the actual augmentation of each tooth position was 352.94 mm(3)(159.24-501.78), the accuracy of the final actual augmentation reached 95.82% (range from 88.53% to 99.15%). Conclusion This case series suggests that a virtually digital guided bone regeneration (GBR) workflow is precise and controllable. The practicality, safety and effectiveness of this procedure needs to be compared to other bone augmentation procedures in randomized controlled trials.
更多
查看译文
关键词
bone augmentation, guided bone generation, labial bone resorption, titanium mesh
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要