Reliability and Reproducibility of the Diameters Method in Rapid Determination of Acute Infarct Volume in Magnetic Resonance Diffusion-Weighted Imaging.

CEREBROVASCULAR DISEASES(2020)

引用 3|浏览44
暂无评分
摘要
BACKGROUND:In acute ischemic stroke, diffusion-weighted imaging (DWI) volume is an independent predictive factor of poor outcome and an exclusion criterion for thrombolytic treatment. A simplified diameters method (ABC/2, orthogonal diameter [OD], and the maximum diameter [MD]) was proposed to replace the conventional measuring method and overcome the tedious and time-consuming defects, but its accuracy remains to be determined. OBJECTIVE:The objective of this study is to clarify the reliability and reproducibility of the diameter-based estimations in the infarct volume in DWI (Vol-DWI) measured by automated software. METHODS:Data of 316 patients with acute ischemic stroke who underwent MRI within 72 h at Jinling Hospital were retrospectively reviewed. Subgroup analysis by the location (cortex, white matter and deep gray nuclei, and combined) and volume (<70 and >70 mL) of cerebral infarction was evaluated. Relationship and consistency between the diameters methods and Vol-DWI were determined using Spearman rank correlation, Wilcoxon signed-rank test, and Bland-Altman plots. The OD and MD thresholds indicating infarct size >15, 70, and 100 mL were determined by generating receiver-operating characteristic (ROC) curves. Interobserver reliability was established using intraclass correlation coefficient and Bland-Altman plot. RESULTS:There was a strong positive correlation between the diameters and the Vol-DWI (ABC/2: r = 0.992, OD: r = 0.984, MD: r = 0.970, p < 0.001). Infarct volumes measured using the ABC/2 formula were significantly lower than those measured with Vol-DWI (Wilcoxon signed-rank test, z = 6.476, p < 0.001). Bland-Altman plot showed that the agreement of the volume <70 mL group, and white matter and deep gray nuclei groups was better than that of the other subgroups. For infarct volumes >15, 70, and 100 mL, the cutoff value for the MD was identified at 5, 6.9, and 8.4 cm, and the OD was identified at 12.47, 26.4, and 36.4 cm2, respectively, with a sensitivity and specificity >90%. CONCLUSIONS:The MD method was the best for achieving a rapid and excellent interobserver reliability for estimating infarct volume. Both OD and MD methods can quickly screen patients suitable for recanalization treatment and predict poor prognosis through threshold evaluation.
更多
查看译文
关键词
Acute ischemic stroke, Diffusion magnetic resonance imaging-diffusion-weighted imaging, Infarct volume determination, Magnetic resonance imaging
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要