Reliability Of Actigraph Gt3x+Placement Location In The Estimation Of Energy Expenditure During Moderate And High-Intensity Physical Activities In Young And Older Adults

JOURNAL OF SPORTS SCIENCES(2021)

引用 11|浏览5
暂无评分
摘要
WHO defines physical activity (PA) as any bodily movement produced by skeletal muscles that requires energy expenditure (EE). The purpose of this study was to compare the EE estimations by ActiGraph GT3X+ with a gold standard measurement, the portable gas analyser in a set of 3 different PAs. This cross-sectional study involved 56 participants, age range (years, [min, max]: young people [20, 33], older adults [65, 83]). Participants completed a single session of three experimental PAs including biking, treadmill walking, and treadmill running. Each participant wore five GT3X+ triaxial accelerometers and a portable gas analyser used as the gold standard measurement. The GT3X+ were placed on the wrists, the waist (centred at the pelvis), and the ankles. ActiGraph GT3X+ and MetaMax3B records were investigated through intraclass correlation coefficient. Magnitude of measurement error was estimated using Effect Size. The GT3X+ wrist and GT3X+ waist underestimated EE regardless of the PA type. The GT3X+ ankles strongly overestimated EE during biking (mean bias = 489 +/- 392%) and walking (mean bias = 106 +/- 58%), while it underestimated EE during running (mean bias = -47 +/- 27%). The ActiGraph GT3X+ does not provide accurate EE estimates across a range of placement locations during moderate and high-intensity PA.
更多
查看译文
关键词
Accelerometer, Actigraph GT3X+, energy expenditure, exercise, ageing