谷歌浏览器插件
订阅小程序
在清言上使用

MIPO Helical Pre-Contoured Plates in Diaphyseal Humeral Fractures with Proximal Extension. Surgical Technique and Results.

Injury(2021)

引用 7|浏览4
暂无评分
摘要
Introduction: The aim of this study was to determine the feasibility of applying the MIPO technique with a helical-shaped plate in the treatment of humeral shaft fractures with proximal extension. Patients and methods: We present an observational prospective study of patients with a humeral shaft fracture involving the proximal humerus fixed with a long proximal humerus polyaxial locking plate with an anterior curvature and helical shape (ALPS (R) Zimmerbiomet, Warsaw, Indianapolis, USA), using a MIPO technique. Between January 2017 and July 2020, 15 patients were treated at our institution. Proximally a 4-5 cm anterolateral transdeltoid approach was made. And distally, a 5-7 cm incision was made 4 cm proximal to the elbow crease. At each follow-up, radiographs were taken to evaluate fracture healing. Funtional scales were applied to evaluate clinical results. Results: Ten women and five men were included, with a mean age of 62 yo (range 26-86). All but one fracture healed uneventfully. The mean time to union was 28 weeks (range 12-48 weeks). Two out of 15 patients presented complications (an atrophic nonunion and a peri-implant distal fracture). None of the patients had a nerve palsy prior neither after the surgery. No other complications, including infection, were registered during follow-up. Shoulder range of motion showed the following means: abduction of 147 degrees (range 50 degrees-180 degrees), anterior flexion of 144 degrees (range 80 degrees-180 degrees), external rotation of 77,5 degrees (range 70 degrees-80 degrees) and internal rotation of 54.5 degrees (range 45 degrees-60 degrees). All patients recovered their pre-fracture elbow range of motion. All patients presented less than 10 degrees of angular deviation in varus/valgus or ante/recurvatum after the surgical procedure. At the end of the follow-up, all final functional scores were "good" or "excellent": mean Constant-Murley score was 72 +/- 13 (range 38-91), ASES score was 73 +/- 12 (range 41-88), UCLA shoulder scale was 30 +/- 3,5 (range 10-35), and Q-DASH score was 16.5 +/- 0,11 (range 4-57). Conclusion: When applied correctly, the treatment of diaphyseal humeral fractures involving the proximal humerus using a polyaxial locking helical plate with a MIPO technique is a reliable treatment method. It has high union rates with low complications. (c) 2021 Elsevier Ltd. All rights reserved.
更多
查看译文
关键词
Humeral combined fracture,Humeral shaft fracture,Proximal humeral fracture,Plate,Helical plate,Bent plate,Minimally invasive plate osteosynthesis,Mipo,Fracture fixation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要