Fully Automated 3D Segmentation and Diffeomorphic Medial Modeling of the Left Ventricle Mitral Valve Complex in Ischemic Mitral Regurgitation.

Medical image analysis(2022)

引用 1|浏览32
暂无评分
摘要
There is an urgent unmet need to develop a fully-automated image-based left ventricle mitral valve analysis tool to support surgical decision making for ischemic mitral regurgitation patients. This requires an automated tool for segmentation and modeling of the left ventricle and mitral valve from immediate pre-operative 3D transesophageal echocardiography. Previous works have presented methods for semi-automatically segmenting and modeling the mitral valve, but do not include the left ventricle and do not avoid self-intersection of the mitral valve leaflets during shape modeling. In this study, we develop and validate a fully automated algorithm for segmentation and shape modeling of the left ventricular mitral valve complex from pre-operative 3D transesophageal echocardiography. We performed a 3-fold nested cross validation study on two datasets from separate institutions to evaluate automated segmentations generated by nnU-net with the expert manual segmentation which yielded average overall Dice scores of 0.82±0.03 (set A), 0.87±0.08 (set B) respectively. A deformable medial template was subsequently fitted to the segmentation to generate shape models. Comparison of shape models to the manual and automatically generated segmentations resulted in an average Dice score of 0.93-0.94 and 0.75-0.81 for the left ventricle and mitral valve, respectively. This is a substantial step towards automatically analyzing the left ventricle mitral valve complex in the operating room.