Active Damping Control and Parameter Design Method for ISOP-Based Load Converter in DC Distribution System

IEEE Journal of Emerging and Selected Topics in Power Electronics(2023)

引用 1|浏览11
暂无评分
摘要
To meet the diversified requirements of active damping configuration in a dc distribution system, the input-series-output-parallel (ISOP) load converter based on phase-shifted full-bridge (PSFB) modules is investigated in this article. The reduced-order impedance model of the PSFB-based ISOP converter with common-duty-ratio control is established first, and then the active damping control strategies using the primary- and secondary-side voltages are proposed, respectively. By reformulating the stability criterion in the form of impedance-frequency curves and using the impedance sensitivity, the sensitivity of resonance frequency is derived to develop a method for designing the parameters of active compensators. Finally, the experimental results demonstrate the effectiveness of the proposed active damping control strategies and parameter design method.
更多
查看译文
关键词
Active damping,criterion reformulation,impedance modeling,input-series output-parallel (ISOP) converter,sensitivity