Chrome Extension
WeChat Mini Program
Use on ChatGLM

Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin(2023)

Cited 1|Views24
No score
Abstract
Purpose Preprocedural computed tomography (CT) imaging before transcatheter aortic valve implantation/replacement (TAVI/TAVR) requires high diagnostic accuracy without motion artifacts. The aim of this retrospective study is to compare the image quality of a high-pitch non-electrocardiography (ECG)-gated CT protocol used in patients with atrial tachyarrhythmias with a prospectively ECG-gated CT protocol used in patients with sinus rhythm. Materials and Methods We retrospectively included 108 patients who underwent preprocedural CT imaging before TAVI/TAVR. 52 patients with sinus rhythm were imaged using a prospectively ECG-gated protocol (Group A), and 56 patients with atrial tachyarrhythmias were imaged using the high-pitch non-ECG-gated protocol (Group B). Image quality was rated subjectively by two experienced radiologists and assessed by objective parameters including radiation dose, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) at the levels of the aortic root and abdominal aorta. Results Subjective image quality was equally good with both CT protocols, and interrater agreement was substantial in both groups but tended to be higher in Group B at the level of the aortic root (Group A: kappa w = 0.644, Group B: kappa w = 0.741). With the high-pitch non-ECG-gated CT protocol, image noise was significantly increased (p = 0.001), whereas the SNR, CNR, and radiation dose were significantly decreased (p = 0.002, p = 0.003, and p < 0.001, respectively) at the level of the aortic root compared to the prospectively ECG-gated CT protocol. Conclusion The high-pitch non-ECG-gated protocol yields images with similar subjective image quality compared with the prospectively ECG-gated CT protocol and allows motion-free assessment of the aortic root for accurate TAVI/TAVR planning. The high-pitch non-ECG-gated protocol may be used as an alternative for preprocedural CT imaging in patients with atrial tachyarrhythmias. Citation Format Shnayien S, Beetz N, Bressem KK et al. Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR. Fortschr Rontgenstr 2022; DOI: 10.1055/a-1898-6504
More
Translated text
Key words
aortic valve,cardiac,CT-angiography
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined