Pitfalls and limitations in the assessment of the HV interval in a Transcatheter Aortic Valve Replacement population. A prospective analysis

C. Teres, C. Haddad,M. Pagnoni,M. Le Bloa, C. Herrera-Siklody, G. Domenichini, A. Porretta,E. Pruvot,P. Pascale

SWISS MEDICAL WEEKLY(2022)

引用 0|浏览11
暂无评分
摘要
Abstract Funding Acknowledgements Type of funding sources: None. Introduction identification of patients with new-onset conduction disturbances at risk of AV-block remains a major unmet challenge in Transcatheter Aortic Valve Replacement (TAVR). His-Ventricular interval (HVI) measurement has been proposed in patients at risk. However, the HVI assessment is often overlooked, performed as a single assessment without active mapping, and even single-catheter assessment is sometimes performed. Purpose To systematically evaluate HVI measurements in a post TAVR population, in search of methodological pitfalls as related to outcomes Methods Consecutive patients who underwent HVI assessment post-TAVR between June 2014 and December 2021. HV interval was classified as normal (<55), intermediate (55-70) and abnormal (>70 ms). Incremental atrial pacing was performed whenever possible. All tracings were reviewed by two blinded operators. Pitfalls in the assessment of atrioventricular conduction were categorized into types 1 to 5, as reported in Table 1. In sinus rhythm, only proximal HVI were considered defined as the concomitant recording of a near-field atrial signal. Results 90 cases were analyzed; median age 81 years1 [76 – 86] years; 37 (41%) male. The median HV interval was 54 [50 – 65] ms. An abnormal HV interval, exceeding the 55 and 70ms cut-off values, was found in 41 (45.9%) and 13 (14.8%) patients, respectively. At least one pitfall was found in 15 patients (16%). Short-term AV block occurred in 3 patients in sinus rhythm in whom no incremental pacing was performed, and in 2 patients with AF despite normal or borderline HVI in both groups. Conclusions Pitfalls in the assessment of the HVI are often observed after TAVR. Identification of infra- and especially intra-His disorders requires careful mapping and must be an active process on behalf of the operator. Our results call into question the value of the HV assessment using a single catheter or in patients with atrial fibrillation, considering the value of incremental atrial pacing and the inherent limitations in AF to assess the most proximal His or intraHis block.
更多
查看译文
关键词
aortic valve replacement,hv interval,aortic valve
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要