Background Despite increasing use of continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion (CSII, insulin pumps) in type 1 diabetes (T1D) in pregnancy, achieving recommended pregnancy glycaemic targets (3.5–7.8 mmol/L or 63–140 mg/dL) remains challenging. Consequently, the risk of adverse pregnancy outcomes remains high. Outside pregnancy, hybrid closed-loop (HCL) insulin delivery systems have led to a paradigm shift in the management of T1D, with 12% higher time in glucose target range (TIR) compared to conventional CSII. However, most commercially available HCL systems are currently not approved for use in pregnancy. This study aims to evaluate the efficacy, safety and cost-effectiveness of the MiniMed™ 780G HCL system (Medtronic) in T1D in pregnancy. Methods In this international, open-label, randomized controlled trial (RCT), we will compare the MiniMed™ 780G HCL system to standard of care (SoC) in T1D in pregnancy. Women aged 18–45 years with T1D diagnosis of at least one year, HbA1c ≤ 86 mmol/mol (≤ 10%), and confirmed singleton pregnancy up to 11 weeks 6 days will be eligible. After providing written informed consent, all participants will wear a similar CGM system (Guardian™ 3 or Guardian™ 4 CGM) during a 10-day run-in phase. After the run-in phase, participants will be randomised 1:1 to 780G HCL (intervention) or SoC [control, continuation of current T1D treatment with multiple daily injections (MDI) or CSII and any type of CGM] stratified according to centre, baseline HbA1c (< 53 vs. ≥ 53 mmol/mol or < 7 vs. ≥ 7%), and method of insulin delivery (MDI or CSII). The primary outcome will be the time spent within the pregnancy glucose target range, as measured by the CGM at four time points in pregnancy: 14–17, 20–23, 26–29, and 33–36 weeks. Prespecified secondary outcomes will be overnight TIR, time below range (TBR: <3.5 mmol/L or < 63 mg/dL), and overnight TBR. Other outcomes will be exploratory. The planned sample size is 92 participants. The study will end after postpartum discharge from hospital. Analyses will be performed according to intention-to-treat as well as per protocol. Discussion This large RCT will evaluate a widely used commercially available HCL system in T1D in pregnancy. Recruitment began in January 2021 and was completed in October 2022. Study completion is expected in May 2023. Trial registration ClinicalTrials.gov: NCT04520971. Registration date: August 20, 2020. https://clinicaltrials.gov/ct2/show/NCT04520971
更多
查看译文
关键词
Artificial pancreas,Automated insulin delivery,Closed-loop insulin delivery,Pregnancy,Type 1 diabetes mellitus
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要