谷歌浏览器插件
订阅小程序
在清言上使用

Risk of Recall Associated with Modifications to High-risk Medical Devices Approved Through US Food and Drug Administration Supplements.

JAMA network open(2023)

引用 1|浏览6
暂无评分
摘要
IMPORTANCE High-risk medical devices approved by the US Food and Drug Administration (FDA) can undergo modifications to their original premarket approval (PMA) via 1 of 5 types of supplements. Only panel track supplements (approximately 1%) require clinical data for approval. The association between device modifications and risk to patient safety has not previously been analyzed. OBJECTIVE To determine the association between PMA supplements and the risk of any device recall and high-risk (class 1) recall. DESIGN, SETTING, AND PARTICIPANTS In this cohort study, the FDA database was queried for original devices approved via PMA from January 1, 2008, through December 31, 2019. Supplement and recall data were obtained for these devices from January 1, 2008, through December 31, 2021, giving a minimum 2-year follow-up after initial approval. Data were analyzed from July 6 to August 6, 2022. Retrospective, time-to-event analysis investigated the association between the number and type of supplements and risk of recall. EXPOSURES Supplements submitted by manufacturers for FDA approval to modify devices. MAIN OUTCOMES AND MEASURES A mixed-effects Cox proportional hazards regression model with frailty terms was used, modeling device recall as an outcome variable during the observation period. A second model was performed for class 1 (high-risk) recall. Explanatory variables are the number of supplements, number of panel track supplements, and cardiovascular devices. Multivariable analysis was performed to identify independent risk factors for recall with hazard ratios (HRs) as the main end point. RESULTS A total of 373 original PMA devices with 10 776 associated supplements were included in the analysis. A median 2.5 (IQR, 1.2-5.0) supplements per device were approved annually. Cardiovascular devices contributed 138 supplements (37.0%), followed by microbiology with 45 (12.1%). No other specialty contributed more than 10%. Multivariable analysis demonstrated that each increase of 1 supplement per year was associated with increased risk of recall (HR, 1.28 [95% CI, 1.15-1.44]; P <.001). For class 1 recall, increased number of supplements (HR, 1.32 [95% CI, 1.06-1.64]; P =.01) and cardiovascular vsnoncardiovascular classification of devices (HR, 3.51 [95% CI, 1.15-10.72]; P =.03) were significantly associated with an increased risk of recall. CONCLUSIONS AND RELEVANCE The findings of this cohort study suggest that PMA supplements are associated with an approximately 30% increased risk of any recall and class 1 recall. The FDA processes for approving modifications to high-risk medical devices should be reevaluated to optimize patient safety and public health.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要